EN
2 - INFORMATION FOR USE
KID 80 SIV
2 - Pag. 32 / 71
no. 14 Pulse number
Defines the number of pulses that the bar receives
so as to simplify its feeding into the lathe collet.
It is active in any point inside the "pulse window".
Description of the phase order:
- the bar enters the pulse phase;
- the bar meets the obstacle (the collet); the
pulses start;
- the bar exits the pulse phase.
Subparameters for setting the pulse window:
M - Pulse phase window start referred to (C);
N - Pulse phase window end referred to (I), the
"collet entry slowdown" (G) simultaneously
ends.
INFORMATION
To prevent unnecessary machine stops,
it is recommended to enter a high value in the subparameter (M).
INFORMATION
If the bar meets an obstacle before entering the pulse window section, the bar
feeder goes into "ALARM" (15 Stationary position before pulses).
C = Collet outer alignment Parameter 64;
I = Facing (Parameter 64 + Parameter 2), in the
example in the picture the hypothetical value
entered in Parameter 2 = 100 mm. The value can
be either positive or negative, for further
information see Parameter 2.
14
no. 14 Pulse number
Pul.with closed collet
20 0
with closed collet
Pulse window start
+400.000 mm
Pulse window end
+20.000 mm
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
A 20
/
M 400
/
N 20
/
All manuals and user guides at all-guides.com
Содержание KID 80-IV Touch
Страница 2: ...All manuals and user guides at all guides com...
Страница 4: ...All manuals and user guides at all guides com...
Страница 14: ...All manuals and user guides at all guides com...
Страница 86: ...All manuals and user guides at all guides com...
Страница 101: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 15 23 All manuals and user guides at all guides com...
Страница 110: ...All manuals and user guides at all guides com...