3 - INFORMATION FOR SET UP
KID 80 SIV
EN
3 - Pag. 21 / 23
3.7
GENERAL PARAMETERS: DESCRIPTION
no. 89 Fair demo
0 - off
1 - on
To activate this mode, it is necessary to set
parameter 35 at 1, parameter 6 (for example)
at 200 mm, and parameter 85 "Bar Change" at
1.
To activate this mode, it is necessary to set
parameter 35 at 1, parameter 6 (for example)
at 200 mm, and parameter 85 "Bar Change" at
1.
no. 90 Wrong bar feeder phase
0 - (K37 active with closed guide channels
in manual mode).
During the "MANUAL" cycle, the bar feeder goes
into "ALARM" when performing movements (for
example "guide channel opening"). The bar
feeder "WORKING" phase is lost and must be
re-established; the "BAR FEEDER WAITING"
message will be displayed.
1 - (Bar feeder in manual mode and lathe
in automatic mode).
At the first bar feeding signal, the bar feeder
goes into "ALARM" mode if it is in manual
mode.
WARNING - CAUTION
After the "MANUAL/AUTOMATIC" lathe signal is given, this safety is not
activated if the bar feeder is working in "MANUAL" mode from the lathe.
89
no. 89 Fair Demo
ON
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
ON ON/OFF
90
no.90 Wrong bar feeder phase
0-K37 active with closed guide channels in the manual mode
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
0 0/1
All manuals and user guides at all-guides.com
Содержание KID 80-IV Touch
Страница 2: ...All manuals and user guides at all guides com...
Страница 4: ...All manuals and user guides at all guides com...
Страница 14: ...All manuals and user guides at all guides com...
Страница 86: ...All manuals and user guides at all guides com...
Страница 101: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 15 23 All manuals and user guides at all guides com...
Страница 110: ...All manuals and user guides at all guides com...