4 - HANDLING AND INSTALLATION
BOSS332/545/551 E-volution
4 - Pag. 32 / 32
4.10
PNEUMATIC CONNECTION
• Fill the tank of lubricator "A" removing plug
"B" or cup "C"; the oil level must reach the
MAX. reference.
For the oil comparison table, see section 2.6.
• Connect pipe "D" (1/4"Gas)to the compressed
air ductwork system as shown in the figure,
after connecting a three-way valve to adjust
and release pressure. With knob "E", adjust
the pressure at 6 bar.
• Check air lubrication (1-12 drops per 1000 l.
of air); adjust by turning the screw "F".
IMPORTANT:
Air must be filtered.
4.11
SOFTWARE PARAMETRING
There should be an adequate parametring of the bar feeder software according to the working
needs and to the type of lathe.
To obtain any information about how to carry out this operation, check the "Push-button panel
instruction manual".