4 - HANDLING AND INSTALLATION
BOSS332/545/551 E-volution
GB
4 - Pag. 5 / 32
4.3
INSTALLATION AREA - CHARACTERISTICS
The floor should be stable and levelled to guarantee good fastening to the ground.
Provide an area of suitable dimensions according to the type of feeder use.
The areas: "D" (work area), "E" (bar feeding area) and "F" (remnant discharge area) should be
properly delimited to prevent collisions between the operator and any handling equipment or
transport vehicles travelling near the bar feeder.
The selected bar feeder setting should be suitably lit and provided with an electric power and
air outlets.
During operation, the feeder will release small amount of oil vapors. Make sure that the
premises where the feeder is installed are suitably ventilated.
The feeder has not been designed and built for use in an explosive atmosphere.
1-2
Without axial displacement
3-4
With axial displacement
Table 1. Overall dimensions
Model
Version
A (mm)
B (mm)
C (mm)
21
2603
32
3802
37
4342
BOSS 332/332r
BOSS 545/545r
BOSS 551/551r
44
5002
605
640