I
E
M
I N D U S T R I A L E Q U I P M E N T A N D M A C H I N E R Y G M B H
Tel. +49(0)6131/914694 • Fax +49(0)6131/963109
E-Mail:
• Web Shop:
http://www.waterpilot.de
• internet:
www.iemgmbh.de
Mounting of the both Parts to the Water Pipe Net:
Mounting of the Ball Valve to the Feed Water: wrap 3 to 4 Layers of Teflon Band around the Outer Thread of
the Ball Valve and screw it inside the Feed Water Connector.
Remove the Cold Water Connector below the Sink from the ½”-Connection (mostly Angle Valve).
Mount the Thread Nipple and reconnect the ½”-Connector (Don´t forget to seal the Threads with Teflon
Band!).
Drain Clamp
Connection to the Drain Pipe:
1. The Drain Clamp has to be mounted to the upright Drain Pipe of the Sink, in front of the Sifon.
2. Drill a 6mm Hole into the Drain Pipe.
3. Bond the Sealing on the Adapter.
4. Fit the Adapter to the Drain Pipe (Holes to be centered by Drill).
5. Do not tighten the screws too hard.
Connecting of the Tubes
1. Connect the white Tube to the Feed Water Connector (max. Salinity of Feed Water: 600 ppm).
2. Connect the blue Tube with the Product Water Faucet.
3. Connect the black Tube to the Drain Clamp.
Initation of the RO Unit
1. Connect the Unit to the Power Socket and switch on the Master Switch at the back of the Unit.
2. Open the Feed Water, in order to check the Unit for leaking Connections.
3. After a few Minutes the Water will flow out of the Product Water Faucet.
(can last up to 5 Minutes, according to Water Pressure).
4. Let the Water flow for approx. 30 Minutes, to rinse the Filters sufficiently.
5. After that close the Product Water Faucet. Now the Storage Tank gets filled.
6. When the Tank is full, please drain it completely.
*** Please do not use the Water of the first Flushing of the Storage Tank!***
*** Now the Unit is completely flushed and ready for Use.***
Controller
The Controller is mounted on the Front Side of the Housing below the Covering.
Possible Errors
Causes
Leaking
The Unit is leaky.
Low Pressure
The Feed Pressure is below 1 bar, increase the
Pressure.
Conductivity too high
The Unit is defect or the Membrane is deficient.
LED „Abnormal“ blinks
The Unit is defect.
LED „Filter“ blinks
The Filters need to be changed.
Installation of the Feed Water Connector