Preparations before the Installation 

1.  The Unit can operate horizontal as well  as in vertical Position. We recommend the vertical Installation 

because of the easier Way to change the Filters. Please be sure to have enough Space for the Replacement 
of the Filters. At the same Time the Unit should be installed near the Water Supply to avoid Pressure Drops 
through short Pipes.  

2.  The Tank should be positioned, where it doesn´t displace. It doesn´t need to be fixed and can be displaced 

later, if necessary. 

3.  The Tap should be positioned, so that the Water can drain into a Sink. When Mounting, please be sure, that 

there is enough Space for the Faucet. 

 

Mounting of the Faucet 

1.  For the Faucet you need a Boring of Ø12mm. For Stainless Steel Sinks we recommend a Tapered Drill (No. 

11802/3-14mm). 

2.  For wooden Counter Tops up to 25mm Thickness, you can use a Wood- or Metal Drill. 
3.  For wooden  Counter Tops up to 40 mm Thickness, you need to countersink min. 15mm from the Bottom, 

using a  Fortner-Drill (Ø40mm- No. 79510/40mm). Drill with a small Borer from the Bottom to the Top and 
afterwards rebore the Hole from the Top, using a 12mm Drill. 

4.  To tighten the Armature you need a 14mm Für das Festziehen der Armatur (Einbauhahn) benötigen Sie 

einen 14mm Socket Wrench (Nr. 62010/14x15). Please position the Plates and Seals as shown below and 
tighten the Nut. 

 

 

 
Installation of the des Water Connection 

 

*** Please be sure, that the Water is shut off, before working on the Water Pipe Net. *** 

 
For the Water Connection, we enclosed two Parts: 

§ 

Feed Water Connector (A130) with ½” Inner- and ½” Outer Thread, with ¼” Inner Thread for the 
Connection of the Ball Valve (A200) 

§ 

Ball Valve (A200) with 1/4“ Inner– and Outer Thread 

  

 

 

 

Feed Water Connector  (A130)   

Ball Valve (A200) 

Содержание Umwelt 3

Страница 1: ...ww waterpilot de internet www iemgmbh de Reverse Osmosis Unit UMWELT 3 Installation and Instruction Manual This Installation and Instruction Manual shows you all the steps for the Installation of the Reverse Osmosis Water Filtration Unit which can be easily done by you If you don t want to install it yourself please contact am adequate plumber on location ...

Страница 2: ...g of the Faucet 1 For the Faucet you need a Boring of Ø12mm For Stainless Steel Sinks we recommend a Tapered Drill No 11802 3 14mm 2 For wooden Counter Tops up to 25mm Thickness you can use a Wood or Metal Drill 3 For wooden Counter Tops up to 40 mm Thickness you need to countersink min 15mm from the Bottom using a Fortner Drill Ø40mm No 79510 40mm Drill with a small Borer from the Bottom to the T...

Страница 3: ...or max Salinity of Feed Water 600 ppm 2 Connect the blue Tube with the Product Water Faucet 3 Connect the black Tube to the Drain Clamp Initation of the RO Unit 1 Connect the Unit to the Power Socket and switch on the Master Switch at the back of the Unit 2 Open the Feed Water in order to check the Unit for leaking Connections 3 After a few Minutes the Water will flow out of the Product Water Fauc...

Страница 4: ...sensitivity 7 Buzzer It will alarm when running abnormal 8 Plug of flow meter It can calculate and display the life of filter by way of flow meter 9 Plug of LCD display board Security Advices The RO Unit is constructed for a Water Pipe Pressure of 3 5 bar In case of a lower Pressure the Quantity and Quality of the Product Water will degrade In Order to counter this you should plump for an RO Unit ...

Отзывы: