Cable routing
For all moving cables, suitable cable routing has to be used to effectively prevent cable breaks.
The minimum radius rmin for cable routing chains is calculated for IEF-Werner cables according to
the following formula:
r
min
≥
10 x cable diameter
When different cables are used, EN 60204 must be observed. In addition, it must be ensured that a
space reserve of 30% is kept free within the routing chains. A strain relief for the cables has to be
attached at the outlet of the cable routing chain.
We recommend purchasing genuine cables and energy chains of IEF-Werner GmbH.