Network link speed
Ethernet physical link speed. “Auto” means the speed is automatically selected by
the converter. You can also specify “10Mbps” or “100Mbps” to match the speed of
the HUB.
□
□
□
DHCP client
DHCP client mode could be enabled/disabled statues. If DHCP is enabled, there
should be a DHCP server on the network. If DHCP is disabled, [IP address],
[Subnet mask], and Gateway address] should be manually assigned.
□
□
□
Socket port of HTTP setup
The socket port used to conduct the browser setup. Normally, HTTP protocol use
TCP port “80” for communication. If the field is changed to “81”, the port “80” will be
reserved for user's own Web.
To enter the browser setup page, “
:81” should be typed for socket port
“81” and “
” for socket port “80”, where “x.x.x.x” is the converter’s IP
address..
□
□
□
Destination IP address
The server IP address and socket port would be connected in TCP Client and UDP
mode for a certain server IP address.
□
□
□
Destination socket port
The server socket port would be connected in TCP Client and UDP mode for a
certain socket port.
□
□
□
Connection
The connection can be selected in 2 modes.
“ Auto function for connect Automatic of converter”
“Manual function for program control of converter ”