iDTRONIC I-Collect 2.0 Скачать руководство пользователя страница 12

Configuration via Software 

 

I-Collect 2.0 

Page 12 of 15 

 

I-Collect 2.0 

5.3

 

List of functions  

Function

 

Description

 

Enter Setting 

Enter the Setupmode (scan before pairing mode) 

Exit Setup 

Exit Setupmode (if you scanned enter setting, and want to leave setup mode) 

Factory Reset 

Deletes all configuration and data on device 

 

Pairing Mode 

Set the device to Pairing Mode , to connect with PC or Smartphone via Bluetooth  (befiore scan 
enter setting) 

Sleep for 5  sec. 

Device goes into sleep mode after 5 sec. 

Sleep for 10 sec. 

Device goes into sleep mode after 10 sec. 

Sleep for 30 sec. 

Device goes into sleep mode after 30 sec. 

Never Sleep 

The device doesn’t go into standby mode

 

Open  Double-click 
Popup/HID 

Open Double-click Popup/HID (only on IOS) 

Close  Double-click 
Popup/HID 

Close Double-click Popup/HID (only on IOS) 

Normal Mode 

Activates normal Mode 

 Data is output directly via KEMU 

Storage Mode 

Activates Storage Mode -  Data is stored on the device 

Storage 

Data 

Upload 

Upload the stored data via KEMU 

 You have to open up a word proccessing program and have 

this window activated, than you can scan the code and the stored data will be written via KEMU 

Display 

Storage 

Memory 

Displays how much barcodes and transponders you scanned with a counter.  

Erase storage data 

Erase the stored data , which you saved in storage mode 

5.4

 

List of output formats 

 

Working Mode

 

Description

 

Example

 

14443A UID-LSB 

Standard output format 

90249135 

14443A UID- MSB 

Output UID with Most significant byte 

35912490 

Mifare  1k/4k  UID-
LSB+Data 

Output UID+Data in LSB  
(Standard format) 

9024913590249135100804000178a5c53483b51d 

Mifare  1k/4k  UID-
MSB+Data 

Output  UID  +  Data  in  MSB, which  you 
selected on the software 

3591249090249135100804000178a5c53483b51d 

Mifare 1k/4k  Data 

Outputs  only  data,which  you  selected 
on the software in LSB 

90249135100804000178a5c53483b51d 
 

Ultralight Data 

Outputs  only  data,which  you  selected 
on the software in LSB 

047fac5f 
 

15693 UID-LSB 

Standard output format 

29701B06013C16E0 

15693 UID-MSB 

Output UID with Most significant byte 

E0163C01061B7029 

15693 Data 

Outputs  only  data,which  you  selected 
on the software in LSB 

00000000 

 
 
For further questions please contact 

[email protected]

 

 
 

Содержание I-Collect 2.0

Страница 1: ...I Collect 2 0 Operation Manual ...

Страница 2: ...bH Ludwig Reichling Straße 4 67059 Ludwigshafen Germany Deutschland Phone 49 621 6690094 0 Fax 49 621 6690094 9 E Mail info idtronic de Web idtronic de Issue 4 4 25 March 2021 Subject to alteration without prior notice Copyright iDTRONIC GmbH 2021 Printed in Germany ...

Страница 3: ...t Description 5 3 Dimensions in mm 6 4 General operation 7 4 1 System Setup Codes 8 4 2 Change bluetooth name 9 5 Configuration via Software 10 5 1 Windows 10 5 2 Android and IOS 11 5 3 List of functions 12 5 4 List of output formats 12 6 Downloads and support 13 7 Technical Parameters 14 ...

Страница 4: ...e heat It may cause I Collect 2 0 s corruption or explosion If I Collect 2 0 has been left in a car as temperature increases it may cause explosion Do not use I Collect 2 0 in event of thunder and lightning Using I Collect 2 0 in lightning condition can cause electric shock Avoid use of I Collect 2 0 in restricted area It can cause radio interference Avoid use of I Collect 2 0 within aircraft It c...

Страница 5: ...roduct Description LED Indication Description RED Light ON Charging RED Light OFF Not Charging GREEN Light ON Not decoding GREEN Light OFF Coding succeed Single BLUE Light ON Pairing success or USB connecting Dual BLUE flicker alternately Bluetooth HID Pairing mode ...

Страница 6: ...Dimensions in mm I Collect 2 0 Page 6 of 15 I Collect 2 0 3 Dimensions in mm ...

Страница 7: ...device when one blue light and green light on and buzzer sounds means pairing successfully After then open any text access tab the data will be output as keyboard emulation For the RFID Reader when device power on the reader will be on working automatically and when slot the card the card UID will be displayed on any text access tab The internal storage is 2 Megabyte which can store up to 100000 b...

Страница 8: ...nner power on Green LED long bright 2 Scan code of Enter Setup then scan Paring mode and then scan Exit Setup 3 By then Green LED no change TWO Blue LED flicker alternately 4 Wait Blue LED and Green light on and Buzzer beeps then the paring succeed Method 2 1 After scanner power on Green LED long bright 2 Long press button for 8 seconds No release it during this period 3 By then Green LED no chang...

Страница 9: ...16 bytes the Bluetooth will only take the first 16 bytes as Bluetooth name 2 Full Bluetooth name format including Bluetooth name protocol type and you only can change the Bluetooth name After you changed the Bluetooth name all Bluetooth name with different protocol type will change at the same time For example you change Bluetooth name into Scanner in HID mode then the Bluetooth name will be Scann...

Страница 10: ... code Select the function which you want to use than select create code Choose the function which you want to use than select create code Select the output format Select the block Select start adress How many bytes should be output max 16 Scan this code with the I Collect 2 0 to change the settings of the reader Create the Code for scanning with the I Collect 2 0 For further use Input access Key S...

Страница 11: ...ich you want to use than select create code Create the Code for scanning with the I Collect 2 0 Select the output format Select the block Select start adress How many bytes should be output max 16 Scan this code with the I Collect 2 0 to change the settings of the reader Select Keytype for more information refer to mifare documents Input access Key Standard Key is FFFFFFFFFFFF ...

Страница 12: ...ou have to open up a word proccessing program and have this window activated than you can scan the code and the stored data will be written via KEMU Display Storage Memory Displays how much barcodes and transponders you scanned with a counter Erase storage data Erase the stored data which you saved in storage mode 5 4 List of output formats Working Mode Description Example 14443A UID LSB Standard ...

Страница 13: ...f 15 6 Downloads and support Download Software and Manuals http download idtronic de Handheld I Collect 202 0 20Manuals 20and 20Softw are zip Software introduction https www youtube com watch v mgZAXDYMhGk feature you tu be Support support idtronic zendesk com ...

Страница 14: ...1K 4K MIFARE Ultralight MIFARE Ultralight C NTAG 21x MIFARE DESFire MIFARE Plus and all other ISO14443A RFID tags ISO15693 EM4135 EM4043 EM4x33 EM4x35 I Code SLI SLIX M24LR16 64 TI Tag it HF I SRF55Vxx my d vicinity Encoding Imaging sensor 960 640 COMS 1D barcode EAN 8 EAN 13 EAN 13 2 add on EAN 13 5 add on ISSN ISBN UPC A UPC E Code 11 Code 39 Code 93 Code 128 Codabar Industrial 2 of 5 Interleave...

Страница 15: ...I Collect 2 0 Technical Parameters I Collect 2 0 Page 15 of 15 Wireless Parameters Wireless technology Bluetooth Transmit range 15 m Transmit power 20 dBm Receiver power 20 dBm ...

Отзывы: