3.2.1
USB HID Keyboard Emulation
This section provides details on the configurable USB HID keyboard emulation
parameters of the
BLUEBOX
Parameter
Description
Range
Default
Intrachar Time
The time between chars.
Note that this parameter become effective
only after a reboot of the reader.
0 … 990 ms in
10 ms step
20 ms
End of
Message
The end character added to the message.
Note that this parameter become effective
only after a reboot of the reader.
NUL
CR
TAB
NUL
Start of Text
The start text character added to the message.
Note that this parameter become effective
only after a reboot of the reader.
See
description
NUL
End of Text
The end text character added to the message.
Note that this parameter become effective
only after a reboot of the reader.
See
description
NUL
Content Data
Encoding
The message content data encoding.
Note that this setting is not effective if the
spontaneous message content data encoding
setting and/or manipulation settings are different
from the default values.
Note that this parameter become effective
only after a reboot of the reader.
None
Kronotech K20
Decimal D10
None
Message Index
The start position index in the message to remove
leading characters from the message (0 means no
leading characters remove)
Note that this parameter become effective
only after a reboot of the reader.
0 … 255
0
Max Message
Length
The max length of the message (0 means all the
message starting from the index to the end of
message).
Note that this parameter become effective
only after a reboot of the reader.
0 … 255
0
The keyboard emulation parameters are stored in configuration page nr. 0x06
and are managed through the
‘Read RAM/ROM Configuration Parameters’ and
‘Write RAM/ROM Configuration Parameters’ commands as described in protocol
technical manuals where the parameters 1…7 fields and default values are:
1
2
3
4
5
6
7
Содержание BLUEBOX Panel Reader LF
Страница 1: ...BLUEBOX Panel Reader Page 1 of 36 125 kHz RFID System BLUEBOX Panel Reader LF ...
Страница 26: ...BLUEBOX Panel Reader Page 26 of 36 10 Mechanical dimensions Dimensions in mm ...
Страница 32: ...BLUEBOX Panel Reader Page 32 of 36 5 On the next screen choose Advanced Options ...
Страница 33: ...BLUEBOX Panel Reader Page 33 of 36 6 Then click on Startup Settings ...
Страница 36: ...BLUEBOX Panel Reader Page 36 of 36 ...