REVISION C 09/29/14
15
82P33731/33831 EVALUATION BOARD
◦
Finally, FRSYNC & MRFRSYNC can be configured, if needed. Change FRSYNC & MFRSYNC to 1PPS. By default,
the duty cycle of sync outputs is 50/50. If a pulse is desired, click on the applicable check box. The pulse width is
based on OUT01 clock period.
Figure 17. Configure MRSYNC and MRFRSYNC
8.
Connecting to the Board
. GUI Configurations can be made before making the USB/I2C connection to the board.
Alternatively, USB connection to the board can be established before TimingComander GUI configuration. It's
recommended to complete initial configurations before making a USB/I2C connection to the board and write registers into
the device registers. Please follow the steps below in
Figure 18
to make a connection to the board.
Figure 18. Steps to Making Connections and Writing to the Board