background image

 

 

 

IDS X64 Quick Programming Guide   700-398-03A   Issued August 2010 

10 

LOCATION 42 

 

Telephone Number 2 Communications Format   (default = 5) 

 

[#] [INSTALLER CODE] [*] [4] [2] [*] [TELEPHONE NO. 2 COMMUNICATIONS FORMAT] [*] 

 

Telephone No.2 Communications Format

 

= 0 – 8 

 

LOCATION 43 

Telephone Number  3 Communications Format (default = 5) 

 

[#] [INSTALLER CODE] [*] [4] [3] [*] [TELEPHONE NO. 3 COMMUNICATIONS FORMAT] [*] 

 

Telephone No. 3 Communications Format

 

= 0 – 8 

 

LOCATION 44 

Telephone Number 4 Communications Format (default = 5) 

 

[#] [INSTALLER CODE] [*] [4] [4] [*] [TELEPHONE NO. 4 COMMUNICATIONS FORMAT] [*] 

 

Telephone No. 4 Communications Format

 

= 0 – 8 

 

LOCATION 45 

Communication Delay  (default = 0020) 

 

[#] [INSTALLER CODE] [*] [4] [5] [*] [MMSS] [*] 

 

MMSS = 00m01s – 59m59s 

 

LOCATION 46 

Reporting Communications Options 

 

[#] [INSTALLER CODE] [*] [4] [6] [*] [BITMAP] [*] 

 

LED 

On / Off 

Action 

ON 

Tone Dialling Enabled 

OFF 

Pulse Dialling Enabled 

ON 

Join the telephone numbers together 

OFF 

Keep two separate telephone numbers 

ON 

Enable Dual Reporting 

OFF 

Disable Dual Reporting 

 

Default values are shaded 

 

LOCATION 47 

Number of Dial Attempts (default = 6) 

 

[#] [INSTALLER CODE] [*] [4] [7] [*] [NUMBER OF DIAL ATTEMPTS] [*] 

 

Number of dial attempts = 1 – 9, with 0 to disable 

 

 

 

 

 

 

 

 

 

Содержание X64

Страница 1: ......

Страница 2: ...IDS X64 Quick Programming Guide 700 398 03A Issued August 2010 2...

Страница 3: ...defaulted 1 Will default the master user code to 1234 or 123456 if 6 digits are being used Master user code properties will also be defaulted 2 Defaults ALL user codes and their properties 3 Defaults...

Страница 4: ...ype CANNOT be bypassed 04 INSTANT ZONE When the panel is armed the violation of an Instant zone will cause the control panel to register an alarm condition 05 ARM DISARM ZONE The violation of an Arm D...

Страница 5: ...tdown count 1 15 LOCATION 11 Programmable Zone Loop Response Time default 2 INSTALLER CODE 1 1 ZONE LOOP RESPONSE TIME Zone loop response time 1 255 LOCATION 12 Cross zone Delay Time default 0030 INST...

Страница 6: ...the display of bypassed and stay zones when armed OFF Disable the display of bypassed and stay zones when armed 7 ON Enable the siren delay OFF Disable the siren delay 8 ON Enable box tamper monitorin...

Страница 7: ...trouble display 7 ON Enable engineer s reset trouble display OFF Disable engineer s reset trouble display 8 ON Enable box tamper trouble display OFF Disable box tamper trouble display 9 ON Enable bus...

Страница 8: ...Number of Account Code Digits default 4 INSTALLER CODE 2 4 NUMBER OF DIGITS Number of digits 4 or 6 LOCATION 25 Month to Start Daylight Saving default 1 INSTALLER CODE 2 5 MONTH Month 1 12 with 0 to d...

Страница 9: ...INSTALLER CODE 3 4 DOWNLOAD CODE DEFAULT DISABLE Download code default disable 0 or 10 LOCATION 35 Hardware Default Switch Disable default 0 INSTALLER CODE 3 5 HARDWARE DEFAULT SWITCH DISABLE Reset sw...

Страница 10: ...at default 5 INSTALLER CODE 4 4 TELEPHONE NO 4 COMMUNICATIONS FORMAT Telephone No 4 Communications Format 0 8 LOCATION 45 Communication Delay default 0020 INSTALLER CODE 4 5 MMSS MMSS 00m01s 59m59s LO...

Страница 11: ...ER CODE 4 9 NUMBER OF RINGS TO ANSWER Number of rings to answer 1 15 LOCATION 50 Call back Telephone Number INSTALLER CODE 5 0 CALL BACK NUMBER Call back number a maximum of 24 digits LOCATION 51 Tele...

Страница 12: ...d OFF 2 ON Cross zone Enabled 10 ON Stay Profile 2 OFF Cross zone Disabled OFF 3 ON Shutdown Zone Enabled 11 ON Stay Profile 3 OFF Shutdown Zone Disabled OFF 4 ON Silent Zone Enabled 12 ON Stay Profil...

Страница 13: ...rtition number 1 8 HHMM 00h00m 23h59m LOCATION 176 No Movement Alarm End default 0100 INSTALLER CODE 1 7 6 PARTITION NUMBER HHMM Partition number 1 8 HHMM 00h00m 23h59m LOCATION 180 Auto Arm Time defa...

Страница 14: ...NEW INSTALLER CODE LOCATION 198 Download Code default 9999 INSTALLER CODE 1 9 8 NEW DOWNLOAD CODE LOCATION 199 Maintenance Code default 8888 INSTALLER CODE 1 9 9 NEW MAINTENACE CODE LOCATIONS 201 208...

Страница 15: ...Arming with a Key switch 7 ON Enable Forced Arm OFF Disable Forced Arm 8 ON Enable Zone Bypassing OFF Disable Zone Bypassing 9 ON Enable Arm with Zones in the Entry Route Violated OFF Disable Arm with...

Страница 16: ...ues are shaded LOCATION 230 Exit Delay Period default 0030 i e 30 seconds INSTALLER CODE 2 3 0 PARTITION NUMBER MMSS Partition number 1 8 MMSS 00m00s 59m59s LOCATION 231 Primary Entry Delay Period def...

Страница 17: ...2 ON Keypad sleep mode enabled OFF Keypad sleep mode disabled 3 ON Enable Global Keypad Status OFF Disable Global Keypad Status Default values are shaded LOCATION 300 Global Reporting Code 1 INSTALLER...

Страница 18: ...Sub location 5 is Reserved Sub location 6 is Reserved Sub location 7 is Reserved Sub location 8 is Reserved Reporting code 01 FF with 00 to disable LOCATIONS 304 307 Zone Alarm Reporting Code INSTALLE...

Страница 19: ...g Code INSTALLER CODE LOCATION ZONE NUMBER REPORTING CODE Location 328 331 Zone Number 01 64 Reporting code 01 FF with 00 to disable LOCATIONS 332 335 Zone Swinger Shutdown Restore Reporting Code INST...

Страница 20: ...349 Close Reporting Code INSTALLER CODE LOCATION USER REPORTING CODE Location 342 349 User 01 128 Reporting code 01 FF with 00 to disable LOCATIONS 350 357 Stay Close Reporting Code INSTALLER CODE LO...

Страница 21: ...Clear Programmable Zone Expander Outputs on Disarming INSTALLER CODE LOCATION BITMAP Location 381 386 LED Output 1 Output 1 2 Output 2 LOCATIONS 389 Clear Programmable Keypad Outputs on Disarming INS...

Страница 22: ...grammable Output Event Disabled 00 401 Keypad Panic Programmable Output Event Output 1 01 Pulse High 02 402 Keypad Fire Programmable Output Event Output 4 04 Pulse High 02 403 Keypad Medical Programma...

Страница 23: ...r 5 output 1 35 Keypad 2 output 15 Zone expander 5 output 2 36 Keypad 3 output 16 Zone expander 6 output 1 37 Keypad 4 output 17 Zone expander 6 output 2 38 Keypad 5 output 18 Reserved 39 Keypad 6 out...

Страница 24: ...00 5 Dedicated Panic Programmable Output Event Output 01 Pulse High 02 6 Communication Fail Programmable Output Event Disabled 00 7 Telephone Line Tamper Programmable Output Event Disabled 00 8 Telep...

Страница 25: ...put number 1 2 HHMM 00h00m 23h59m with 24h00m to disable LOCATION 447 Keypad Output ON Time default 2400 INSTALLER CODE 4 4 7 OUTPUT NUMBER HHMM Output number 1 8 HHMM 00h00m 23h59m with 24h00m to dis...

Страница 26: ...2 Output 2 467 Zone Expander 3 Output 1 468 Zone Expander 3 Output 2 469 Zone Expander 4 Output 1 470 Zone Expander 4 Output 2 471 Zone Expander 5 Output 1 472 Zone Expander 5 Output 2 473 Zone Expand...

Страница 27: ...Disable zone alarm restore reporting OFF Telephone module 1 3 ON Enable zone bypass reporting 11 ON Telephone module 2 OFF Disable zone bypass reporting OFF Telephone module 1 4 ON Enable zone force...

Страница 28: ...per reporting OFF Telephone module 1 4 ON Enable siren fail reporting 12 ON Telephone module 2 OFF Disable siren fail reporting OFF Telephone module 1 5 ON Enable panel low battery fail reporting 13 O...

Страница 29: ...e module 2 OFF Disable AC restore reporting OFF Telephone module 1 5 ON Enable communications restore reporting 13 ON Telephone module 2 OFF Disable communications restore reporting OFF Telephone modu...

Страница 30: ...e module 1 5 ON Enable bus wired peripheral fail restore reporting 13 ON Telephone module 2 OFF Disable bus wired peripheral fail restore reporting OFF Telephone module 1 6 ON Enable bus wired periphe...

Страница 31: ...oad reporting OFF Telephone module 1 2 ON Reserved 10 ON Reserved OFF Reserved OFF Reserved 3 ON Reserved 11 ON Reserved OFF Reserved OFF Reserved 4 ON Reserved 12 ON Reserved OFF Reserved OFF Reserve...

Страница 32: ...e module 1 3 ON Enable fire reporting 11 ON Telephone module 2 OFF Disable fire reporting OFF Telephone module 1 4 ON Enable medical reporting 12 ON Telephone module 2 OFF Disable medical reporting OF...

Страница 33: ...IDS X64 Quick Programming Guide 700 398 03A Issued August 2010 33...

Страница 34: ...IDS X64 Quick Programming Guide 700 398 03A Issued August 2010 34...

Страница 35: ...IDS X64 Quick Programming Guide 700 398 03A Issued August 2010 35...

Страница 36: ...IDS X64 Quick Programming Guide 700 398 03A Issued August 2010 36...

Отзывы: