IDS X Series Скачать руководство пользователя страница 19

Section: 8 

 

IDS X-series LCD Keypad User Manual   700-411-01D   Issued August 2010 

19 

are disarmed and others armed, entering this group code at the keypad of the armed partition will disarm 

the armed partitions only. 

8.3.7.6

 

Global Arm / Disarm Code                                            

 

This code will either arm or disarm the partitions assigned to that user depending on their status. If both 

partitions  are  disarmed,  entering  a  global  code  will  arm  both  partitions.  If  more  than  one  partition  is 

armed, entering a global code will disarm them. In the case where one partition is armed and another is 

disarmed,  entering  a  global  code  at  the  keypad  of  the  armed  partition  will  disarm  that  partition  and 

entering a global code at the keypad of the disarmed partition will arm that partition. 

8.3.7.7

 

Programmable Output Code                                            

 

Any event, which is able to trigger a programmable output, can be assigned to an output number from 1 

to  41.  Assigning  an  event  to  outputs 1  to  5  will  use  the  panel‟s  onboard  outputs 1  to  5.  Assigning  an 

event to outputs 6 to 25 will use an output on a zone expander or keypad. 

8.3.8

 

Option 11 - Assign User Code to Partitions                              

 

[*] [MASTER CODE] [*] [1] [1] [*] [USER CODE] [*] [PARTITION NUMBER] [*] [*] [#] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of section 8.2. 

2.

 

The LCD display reads „Option Menu‟, „Add User Code‟.  

3.

 

To  select  menu  option  11  –  „User  ->Partitions‟,  press  the  [1]  [1]  keys  or  alternatively  use  the 

[PANIC]  or  [MED]  keys  to  scroll  through  the  list  of  programmable  options  until  you  reach  the 

option you want. 

4.

 

Press the [*] key. 

5.

 

The LCD display reads „User Code + *‟. 

6.

 

Enter the [USER CODE] followed by the [*] key. 

7.

 

The partitions to which the [USER CODE] is assigned are indicated by options 1 - 8. If the user is 

assigned to partition 1, there will be a YES next to option 1 and the user can thus arm and disarm 

partition 1. If the user is assigned to partition 4, there will be a YES next to option 4. It is possible 

to program codes to arm/disarm any combination of the available partitions. 

8.

 

Enter  the  [PARTITION  NUMBER]  followed  by  the  [*]  key.  One  may  also  use  the  [PANIC]  and 

[MED] keys to scroll through the partitions. 

9.

 

Press the [*] key to toggle between YES and NO. 

10.

 

Repeat steps 8 - 9 until the User Code has been assigned to the correct partition(s). 

11.

 

Press the [#] key twice to exit the User Program Mode. 

8.3.9

 

Option 13 – User Outputs                              

 

[*] [MASTER CODE] [*] [1] [3] [*] [USER CODE] [*] [OUTPUT No] [*] [OUTPUT ACTION] [*] [#] 

1.

 

Enter the User Program Mode as per steps 1 - 4 of section 8.2. 

2.

 

The LCD display reads „Option Menu‟, „Add User Code‟.  

3.

 

To select menu option 13 –„User Outputs‟, press the [1] [3] keys or alternatively use the [PANIC] 

or [MED] keys to scroll through the list of programmable options until you reach the option you 

want. 

4.

 

Press the [*] key. 

Содержание X Series

Страница 1: ...IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 1...

Страница 2: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 2...

Страница 3: ...ency Alarms 12 6 1 Fire Alarms 12 6 2 Panic Alarms 12 6 3 Medical Alarms 12 6 4 Duress Alarms 13 7 Alarm Memory 13 7 1 Event Log 13 8 User Codes 14 8 1 Adding Deleting and Editing User Codes 14 8 2 Ho...

Страница 4: ...24 9 2 How to Program Cancel Stay Zones 24 10 Buzz Zones 24 10 1 How to Program Cancel Buzz Zones 25 11 Chime Zones 25 11 1 How to Program Cancel Chime Zones 25 12 Viewing Trouble Conditions 26 13 Ch...

Страница 5: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 5...

Страница 6: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 6...

Страница 7: ...partition number Ready to Arm if there are no violated zones otherwise it will display V zone Number zone name for about 3 seconds for each violated zone EXAMPLE If there are no zone violations the ke...

Страница 8: ...nly via a designated exit route The panel will away arm at the end of the exit delay if any enter exit zone is violated e g the front door 6 Once the panel has armed the LCD display will read Armed al...

Страница 9: ...D Keypad will read Exit Delay the ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay 7 When the panel arms any STAY zones will be automatically bypassed These are...

Страница 10: ...display as flashing text Use the PANIC and MED keys to scroll through zones that have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a design...

Страница 11: ...tion is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 4 2 How to Disarm using a Key Switch or Remote 1 Activate th...

Страница 12: ...a smoke detector connected to an appropriately programmed zone The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company To sil...

Страница 13: ...d buzzer will sound briefly 3 Use the MED or PANIC keys to scroll through the zones violated during the last armed period 4 Press the 1 key to return to violated zones 5 Press the 2 key to display zon...

Страница 14: ...e Table 1 for a summary of programmable options The programmable interface is accessed by entering the USER PROGRAMMING MODE Table 1 User Programming Options Options Summary of Programmable Options Op...

Страница 15: ...Option 0 will be displayed on the LCD screen by default Press the key to confirm your entry Once prompted to Enter a User Code input a NEW USER CODE followed by the key Once the user code is programme...

Страница 16: ...ns until you reach Menu Option 2 Press the key 4 The LCD display reads User Code 5 Enter the USER CODE to be deleted followed by the key Deleting the code in slot one will reprogram it to 1234 6 Furth...

Страница 17: ...play reads User Code 5 Enter the USER CODE followed by the key the slot number is displayed on the keypad 6 Further slot numbers may be viewed by repeating step 5 7 Press the key to exit the User Prog...

Страница 18: ...uder It is advisable to choose a code that can be easily remembered by all family or staff members 8 3 7 3 Maid s Code This code can be used to limit access to the premises A maid s code will only dis...

Страница 19: ...LCD display reads Option Menu Add User Code 3 To select menu option 11 User Partitions press the 1 1 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options...

Страница 20: ...Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone expander 3 output 2 32 Reserved 12 Zone expander 4 output 1 33 Reserved 13 Zone expander 4 output 2 34...

Страница 21: ...5 ON Enable access RC OFF Disable access RC 8 3 11 Option 15 User Reporting Code Telephone Modules MASTER CODE 1 5 USER CODE BITMAP 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The...

Страница 22: ...gh the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads Zone Names Zone Num 6 Enter the ZONE No followed by the key 7 Press the key to begin ent...

Страница 23: ...he User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 41 Edit Date press the 4 1 keys followed by the key or alternatively use...

Страница 24: ...s the key to toggle between YES and NO NOTE Buzz zones will be shown by flashing LEDs See Section 10 A Buzz zone cannot be selected as a Stay Zone The Buzz status must be cleared first 7 Repeat steps...

Страница 25: ...selected as a Buzz zone 11 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated t...

Страница 26: ...ondition has restored To cancel the beeping without viewing the trouble conditions press the key Table 7 Trouble Conditions Zone LED Trouble Condition 1 Panel AC Supply Failure 2 Panel Communications...

Страница 27: ...off 1 Hold MODE down for one second until the keypad beeps twice 2 The LCD display reads Mode Number 3 Press the 3 key followed by the key 4 The LCD display reads Output Num 5 Enter the OUTPUT NUMBER...

Страница 28: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 28...

Страница 29: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 29...

Страница 30: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 30...

Страница 31: ...Codes Enable Master Code 1 4 User Code Bitmap User Reporting Code Telephone Master Code 1 5 User Code Bitmap Edit a Zone Name Master Code 3 0 Zone No Zone Name Edit the Time Master Code 4 0 Time Edit...

Страница 32: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 32...

Отзывы: