3.

 

To select menu option 1 – „Edit User Code‟, press the [1] key or alternatively use the [PANIC] or 

[MED]  keys  to  scroll  through  the  list  of  programmable  options  until  you  reach  the  option  you 

want. 

4.

 

Press the [*] key. 

5.

 

The LCD display reads „Old Code + *‟.  

6.

 

Enter the [USER CODE] you wish to edit followed by the [*] key. 

7.

 

The LCD display reads „New Code + *‟. 

8.

 

Enter the [NEW CODE] followed by the [*] key. To move the cursor within the NEW CODE, use 

the [PANIC] or [MED] keys. 

9.

 

To edit other codes repeat steps 5 - 7. 

10.

 

Press the [#] key to exit the User Program Mode. 

8.3.3

 

Option 2 - Delete User Code (Code known)                               

 

[*] [MASTER CODE] [*] [2] [*] [USER CODE] [*] [#] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of section 8.2. 

2.

 

The LCD display reads „Option Menu‟, „Add User Code‟.  

3.

 

To select menu option 2 – „Delete User Code‟, press the [2] key or alternatively use the [PANIC] 

or [MED] keys to scroll through the list of programmable options until you reach Menu Option 2. 

Press the [*] key. 

4.

 

The LCD display reads „User Code + *‟. 

5.

 

Enter the [USER CODE] to be deleted followed by the [*] key. 'Deleting' the code in slot one will 

reprogram it to 1234. 

6.

 

Further codes may be deleted by repeating step 5. 

7.

 

Press the [#] key to exit User Program Mode. 

8.3.4

 

Option 3 – Add/Edit Code                               

 

[*] [MASTER CODE] [*] [3] [*] [SLOT NUMBER] [*] [USER CODE] [*] [#] 

1.

 

Enter the User Program Mode as per steps 1 - 4 of section 8.2. 

2.

 

The LCD display reads „Option Menu‟, „Add User Code‟.  

3.

 

To select menu option 3 – „Add/Edit Slot‟, press the [3] key or alternatively use the [PANIC] or 

[MED]  keys  to  scroll  through  the  list  of  programmable  options  until  you  reach  the  option  you 

want. 

4.

 

Press the [*] key. 

5.

 

The LCD display reads „Slot + *‟. 

6.

 

Enter the [SLOT NUMBER] to be added/edited followed by the [*] key.  

7.

 

The LCD display reads „New Code + *‟, „Slot number‟. 

8.

 

Enter the [USER CODE] followed by the [*] key. 

9.

 

Further slots may be added/edited by repeating steps 6 - 8. 

10.

 

Press the [#] key to exit User Program Mode. 

8.3.5

 

Option 4 - Delete a User Code ("Slot" known)                                  

 

[*] [MASTER CODE] [*] [4] [*] [SLOT NUMBER] [*] [#] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of section 8.2. 

2.

 

The LCD display reads „Option Menu‟, „Add User Code‟.  

Содержание X Series

Страница 1: ...IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 1...

Страница 2: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 2...

Страница 3: ...ency Alarms 12 6 1 Fire Alarms 12 6 2 Panic Alarms 12 6 3 Medical Alarms 12 6 4 Duress Alarms 13 7 Alarm Memory 13 7 1 Event Log 13 8 User Codes 14 8 1 Adding Deleting and Editing User Codes 14 8 2 Ho...

Страница 4: ...24 9 2 How to Program Cancel Stay Zones 24 10 Buzz Zones 24 10 1 How to Program Cancel Buzz Zones 25 11 Chime Zones 25 11 1 How to Program Cancel Chime Zones 25 12 Viewing Trouble Conditions 26 13 Ch...

Страница 5: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 5...

Страница 6: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 6...

Страница 7: ...partition number Ready to Arm if there are no violated zones otherwise it will display V zone Number zone name for about 3 seconds for each violated zone EXAMPLE If there are no zone violations the ke...

Страница 8: ...nly via a designated exit route The panel will away arm at the end of the exit delay if any enter exit zone is violated e g the front door 6 Once the panel has armed the LCD display will read Armed al...

Страница 9: ...D Keypad will read Exit Delay the ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay 7 When the panel arms any STAY zones will be automatically bypassed These are...

Страница 10: ...display as flashing text Use the PANIC and MED keys to scroll through zones that have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a design...

Страница 11: ...tion is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 4 2 How to Disarm using a Key Switch or Remote 1 Activate th...

Страница 12: ...a smoke detector connected to an appropriately programmed zone The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company To sil...

Страница 13: ...d buzzer will sound briefly 3 Use the MED or PANIC keys to scroll through the zones violated during the last armed period 4 Press the 1 key to return to violated zones 5 Press the 2 key to display zon...

Страница 14: ...e Table 1 for a summary of programmable options The programmable interface is accessed by entering the USER PROGRAMMING MODE Table 1 User Programming Options Options Summary of Programmable Options Op...

Страница 15: ...Option 0 will be displayed on the LCD screen by default Press the key to confirm your entry Once prompted to Enter a User Code input a NEW USER CODE followed by the key Once the user code is programme...

Страница 16: ...ns until you reach Menu Option 2 Press the key 4 The LCD display reads User Code 5 Enter the USER CODE to be deleted followed by the key Deleting the code in slot one will reprogram it to 1234 6 Furth...

Страница 17: ...play reads User Code 5 Enter the USER CODE followed by the key the slot number is displayed on the keypad 6 Further slot numbers may be viewed by repeating step 5 7 Press the key to exit the User Prog...

Страница 18: ...uder It is advisable to choose a code that can be easily remembered by all family or staff members 8 3 7 3 Maid s Code This code can be used to limit access to the premises A maid s code will only dis...

Страница 19: ...LCD display reads Option Menu Add User Code 3 To select menu option 11 User Partitions press the 1 1 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options...

Страница 20: ...Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone expander 3 output 2 32 Reserved 12 Zone expander 4 output 1 33 Reserved 13 Zone expander 4 output 2 34...

Страница 21: ...5 ON Enable access RC OFF Disable access RC 8 3 11 Option 15 User Reporting Code Telephone Modules MASTER CODE 1 5 USER CODE BITMAP 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The...

Страница 22: ...gh the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads Zone Names Zone Num 6 Enter the ZONE No followed by the key 7 Press the key to begin ent...

Страница 23: ...he User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 41 Edit Date press the 4 1 keys followed by the key or alternatively use...

Страница 24: ...s the key to toggle between YES and NO NOTE Buzz zones will be shown by flashing LEDs See Section 10 A Buzz zone cannot be selected as a Stay Zone The Buzz status must be cleared first 7 Repeat steps...

Страница 25: ...selected as a Buzz zone 11 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated t...

Страница 26: ...ondition has restored To cancel the beeping without viewing the trouble conditions press the key Table 7 Trouble Conditions Zone LED Trouble Condition 1 Panel AC Supply Failure 2 Panel Communications...

Страница 27: ...off 1 Hold MODE down for one second until the keypad beeps twice 2 The LCD display reads Mode Number 3 Press the 3 key followed by the key 4 The LCD display reads Output Num 5 Enter the OUTPUT NUMBER...

Страница 28: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 28...

Страница 29: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 29...

Страница 30: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 30...

Страница 31: ...Codes Enable Master Code 1 4 User Code Bitmap User Reporting Code Telephone Master Code 1 5 User Code Bitmap Edit a Zone Name Master Code 3 0 Zone No Zone Name Edit the Time Master Code 4 0 Time Edit...

Страница 32: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 32...

Отзывы: