background image

Diagram References

Specification

Description

4

5

Installation

Detection range

Anti-masking alarm

3

1

2

Enrollment

Masked:

PIR Triggered: (top)
Alarm:

MW Triggered:

(bo

om)

Fault:

+

Detec

on Method

Passive Infrared,Microwave

Detec

on range

15m

Detection angle

90° @ 180° adjustable

Detec

on zone

92

Detectable speed

0.3

2m/s

Sensi

vity

Auto,Low

White

light filter

10000lux

Pet immunity

30Kg

Microwave frequency

24GHz(24.15

24.25GHz)

Digital

temperature compensa�on

Tri-Signal logic

An

-masking

Support
Support

Pattern mask included

Digital processing

Tri-Signal logic

Sealed

op�cs

Support

Tamper

protec�on

Front,Rear

Environment temperature indicator

Support

Signal strength indicator

Support

An

-sway analytics

Support

Power switch

Power up enrolling

LED Indicator

Green(Top PIR), Red(Microwave),

Orange(Bottom PIR), Green+Orange(Mask),

Blue(Alarm)

Transmission technology

Tri-X wireless

Transmission method

Two-Way RF wireless

Transmission frequency

868MHz

Transmission security

AES-128 Encryption

RF Range

1.6Km

Frequency hopping

Support

Enrolling method

Power up, remote ID,QR code

Standard battery life

5 years in work status (being triggered 20

mes

per day)

Power supply

Battery powered

Battery type

CR123A × 5

Typical voltage

3V

Low voltage value

2.45±0.1V

Voltage range

Fully charged(new) to 2.45±0.1V(battery)

Operating temperature

-25 °C to 60 °C (-13 °F to 140 °F)

Storage temperature

-25 °C to 60 °C (-13 °F to 140 °F)

Opera

ng humidity

10% to 90%

IP Rate

IP65

Dimension(WxHxD)

75mm × 202mm × 73mm

Weight

600g

Mounting height

0.8 to 1.2m

Moun

ng method

Wall

Adaptable coverage

Note: This product can only power the camera module as its accessory.

EN 50131-2-4:2020

EN 50131-5-3:2017

EN 50131-1+A1+A2+A3

EC IV

SG 2

Cer

�fi

ed by KIWA

1. LED Indicator 

 

2. Ver�cal pole mount 

3. Screw hole

4. Top/bo�om cover 

5. Front panel

6. PCB

a. PIR Module (Top)  b. PIR Module (Bo�om)

c. Tamper switch       d. Power switch   e. Microwave module

f. Antenna                   g. PIR Angle

7. Rear panel   

I. Enrollment succeeded.

Note: The front panel should be installed before

powering on successfully.

II. Check signal strength. 

I. Detector range

1. PIR Angle se�ngs    2. PIR Distance se�ngs

II. Masking seal 

Product code :  

868-05-050

Helpdesk :

  +27 (0) 87 159 7341

 Wireless outdoor tri-tech anti-masking detector

VX PRO 

VX PRO 

Содержание VX PRO Series

Страница 1: ...Product user manuals SIMPLICITY THROUGH INNOVATION VX PRO SERIES WIRELESS ALARM SYSTEM Version 1 0...

Страница 2: ...standby EN Grade 2 CE Rohs Reach WEEE 557 5 g 19 7 oz IDS VX Pro app Arm Disarm Alarm Tamper Fault Cloud Power SIA 09 Contact ID ISUP 1 1 46 Parameters 64 Series 96 Series RF frequency 1 Func on LED I...

Страница 3: ...8 2 9 2 10 2 11 2 12 2 1 5 3 4 xxxx 5 s 2 1 2 2 OR POWER ON TRIGGER 2 1 Add Device Sites xxx My Device OR Guarding Vision Mobile Client Guarding Vision Pro Note Do not install the device near the hig...

Страница 4: ...ght white Number key 10 0 to 9 Function key 5 stay arming away arming disarming and Humidity 10 to 90 Temperature 10 to 55 Color White Dimension W x H x D 140 x 86 x 22 mm Installation Installation Sc...

Страница 5: ...1 2 5 4 6 3 1 1 2 3 2 3 4 xxxx Device Signal Strength Test...

Страница 6: ...LED Indicator Lock Unlock device RF Frequency 868MHz Ba ery voltage 3V Modula on 2GFSK Min Opera ng voltage 2 1V 5 RF range 800m Standard ba ery life 3 years LED Indicator Three color LED Opera ng te...

Страница 7: ...2 1 3 4 5 2 4 2 2 2 1 4 3 1 2 3 1 2 3 xxxx 3 S 3 S a b c e d...

Страница 8: ...x 1 included Standard ba ery life 3 years 1 LED Indicator 2 Bu on 3 Tamper bu on 4 Ba ery 1 Bu on ac vated 2 Alarm received I Check signal strength II Align the groove to install the detector a With...

Страница 9: ...2 1 3 4 3 2 1 1 2 4 3 5 I II 1 2 Signal Strength Test a b xxxx Device...

Страница 10: ...ission frequency 868MHz RF range 800m Ba ery CR2032 x 1 included Standard ba ery life 3 years EN 50131 1 2006 A2 2017 EN 50131 3 2009 EN 50131 5 3 2017 Security Grade SG 2 Environmental Class EC II Pr...

Страница 11: ...1 2 3 3 2 1 4 1 I II III 2 3 1 2 xxxx Device...

Страница 12: ...ergency button 1 Insert tool into the groove to disassemble the bu on Note Do not disassemble the device with sharp objects 2 Remove the roping shell 3 Align the datum mark and put the bu on into the...

Страница 13: ...1 2 3 4...

Страница 14: ...ty 10 to 90 Dimension W x H x D 102 x 41 x 20 mm Weight 35 g without battery 90 g with battery Installation Put inside wireless weady detector Product code 868 03 015 Helpdesk 27 0 87 159 7341 Wireles...

Страница 15: ...ON OFF ZONE TAMP AM O CR123A CR123A CR123A ON OFF ZONE TAMP AM OUT CR123A CR123A CR123A 1 2 3 6 4 5 1 xxxx Device 2 3 ON OFF ZONE TAMP AM O CR123A ZONE TAMP AM O ON OFF ZONE TAMP a b c d 7 Times 1 2 3...

Страница 16: ...ear tamper proof Siren Decibel 90 to 110 db Opera ng temperature 10 to 55 Opera ng humidity 10 to 90 Installa on Wall moun ng Power General RF Interface Indica on EN 50131 1 2006 A2 2017 EN 50131 4 20...

Страница 17: ...1 3 2 1 2 3 4 1 2 3 4 5 6 7 ON OFF ON OFF ON OFF xxxx 1 2 3 8 Signal Strength Test...

Страница 18: ...to 90 Material PC ABS Protec on level IP65 Installa on Wall moun ng Power General RF Indica on EN 50131 1 2006 A2 2017 EN 50131 4 2019 EN 50131 6 2017 EN 50131 5 3 2017 Security Grade SG Environmental...

Страница 19: ...1 2 4 3 BATTERY POWER 12 VDC POWER 1 1 1 2 3 2 1 2 3 3 2 4 5 6 7 8 9 10 3 O N O FF 12V 12V O N O FF 12V O N O FF 12V O N O FF 12V xxxx 7 mes O N O FF O N O FF O N O FF 12V Signal Strength Test Device...

Страница 20: ...41 Installation 3 1 2 Enrollment Wireless repeater Specification Tamper protec on 1 Front and Back Auto pairing Supported Power switch 1 RF method Two way communica on RF frequency 868 MHz Power suppl...

Страница 21: ...2 1 2 1 2 2 2 4 2 3 3 1 4 5 6 7 2 3 xxxx Device Signal Strength Test I II a b KA3 25...

Страница 22: ...et up with App 5 Power on the transmi er Enrollment completed Flashing green for 7 mes Appearance Product code 868 04 006 Helpdesk 27 0 87 159 7341 1 2 Setup Wireless 16 input transmitter Specificatio...

Страница 23: ...Z15 C Z16 Dry Contact C1 PGM1 a 2 2K 2 2K NC NO Z C TAMPER Detector 2 2k Local Zone Local Zone Security Control Panel Security Control Panel 8 2k Local Expanding Zone Z C C C NO NO 2 2k 8 2k NC C NC C...

Страница 24: ...fication Func on bu on 1 for ini aliza on Scenario se ngs By alarm byopera on by fault byschedule by manual Alarm input 1 for tamper NO NC Relay output 1 NO NC Max 5A at36VDC Voltage protection Suppor...

Страница 25: ...1 3 2 4 5 3 2 1 1 2 xxxx Device IN RELAY PS TAMPER 1 2 3 IN RELAY PS TAMPER Signal Strength Test 2 3 1...

Страница 26: ...t plug Power button 1 for enrollment Scenario setting By alarm by opera on by fault by schedule by manual RF Method Two way communica on RF Frequency 868 433 MHz Power supply 230V 50 60Hz 10A Max 2300...

Страница 27: ...1 3 4 2 1 2 4 3 1 2 3 xxxx 1 2 3 7 Times 3 Times Signal Strength Test 8 s...

Страница 28: ...90 Installation height 1 8 to 2 4m Dimension W H D 65 5mm 103mm 48 5mm Weight 128g Transmission frequency 868MHz RFRange 800m Ba ery CR123A x 1 included Standard ba ery life 3 years Detec on range Spe...

Страница 29: ...Detec on Range 52 zones 4 planes 10m 12m 1m 2m 4m 6m 8m 10m 12m 15m 15m 1m 2 4m 2m 4m 6m 8m 10m 12m 15m 1m 2m 4m 6m 8m 3min 1 2 3 4 7 Times 1 2 3 4 Signal Strength Test or a b xxxx Device I II III 1 2...

Страница 30: ...4 to 3 6m Dimension W H D 65 5mm 103mm 48 5mm Weight 128g Transmission frequency 868MHz RF range 800m Ba ery CR123A x 1 included Standard ba ery life 3 years Low voltage value 2 45 V Specification De...

Страница 31: ...1 2 3 4 7Times 3min 1 2 3 4 Detec on Range 6 3 18 zones 8 planes or a b xxxx Device I II III 1 2 4 3 5 Signal Strength Test...

Страница 32: ...Yes Pet immunity Up to 15Kg Height 30cm Microwave frequency 24Ghz 24 15Ghz to 24 25Ghz Tamper protec on Front back LED indicators Green PIR Orange microwave Blue alarm Opera ng temperature 10 C to 55...

Страница 33: ...5 9 a Detec on Range 52 zones 4 planes 3min 1 2 3 4 7Times 1 2 3 4 Signal Strength Test or a b xxxx Device I II III 1 2 4 3 3 5 10m 12m 1m 2m 4m 6m 8m 10m 12m 1m 2 4m 2m 4m 6m 8m 10m 12m 1m 2m 4m 6m 8...

Страница 34: ...nity Up to 15Kg Height 30cm Camera coverage 88 H 68 V Auto day and night Colour Black White Image size 160x120 320x240 640x480 Tamper protec on Front Back LED indicator Alarm blue signal strength red...

Страница 35: ...n a er the enrollment 1 2 3 4 10m 12m 1m 2m 4m 6m 8m 10m 12m 1m 2 4m 2m 4m 6m 8m 10m 12m 1m 2m 4m 6m 8m 85 9 a Detec on Range 52 zones 4 planes Signal Strength Test or a b I II III 7Times xxxx Device...

Страница 36: ...Enrollment Wireless PIR glass break detector 3 Detec on range 12m 85 9 Auto sensi vity Yes Pet immunity Up to 15kg Height 30cm Detec on range 8m radius Tamper protec on Front Back LED indicator Green...

Страница 37: ...on Range 52 zones 4 planes 1 2 3 4 7Times 1 2 3 4 Signal Strength Test 30Kg or a b xxxx Device I II IV III 1 3 4 5 6 2 10m 12m 1m 2m 4m 6m 8m 10m 12m 1m 2 4m 2m 4m 6m 8m 10m 12m 1m 2m 4m 6m 8m 2s 2s...

Страница 38: ...y life 3 Years Temperature 10 C to 55 C 14 F to 131 F Storage temperature 20 C to 60 C 4 F to 140 F Opera ng humidity 10 to 90 Dimension D D 101 2 mm x 32 9 mm Weight 109 5 g Moun ng height 2 4 to 4m...

Страница 39: ...3min 1 2 3 4 1 2 3 4 Signal Strength Test a b xxxx Device I II 1 4 3 2 o 8m 2 4m 3m 4m 10m 12m 2m 4m 6m 2m 4m 6m 0 2m 4m 6m 2m 4m 6m 0 Zone 172 Plane 3...

Страница 40: ...allation and enrollment 3 1 2 Tri T anti masking detector enrollment RF camera module Field angle 137 2 H 80 1 V Image type JPEG 640 480 320 240 160 120 Fill light Infrared light Fill range 15m Day Ni...

Страница 41: ...3 1 CAM PIR CAM 1 3 L 1 2 3 4 5 6 7 8 9 4 6 M 7 9 R PIR xxxx Area Status Area Status Tri Tech AM Detector All Areas Add Camera XXXXXXXX Device 1 2 3 1 2 6 7 8 5 4 3...

Страница 42: ...mm Weight 85 5 g Transmission frequency 868MHz RF Range 800m Ba ery CR2450 x 1 included Standard ba ery life 3 years Specification Description 1 LED Indicator 2 Extension cable 3 Tamper bu on 4 Probe...

Страница 43: ...1 2 3 4 I II a a b b xxxx Device Signal Strength Test 1 2 3 4 5...

Страница 44: ...Helpdesk 27 0 87 159 7341 Enrollment 2 Test 4 1 Wireless smoke detector Installation 3 Detec on method Chamber with photoelectric sensor Opera on mode Independent wireless repor ng Siren volume 85 dB...

Страница 45: ...1 2 3 4 xxxx 3 S 1 s 1 s 0 5 s 0 5 s 0 5 s 0 5 s 0 5 s 0 5 s 1 2 4 a b c 3 I II Signal Strength Test T E S T H U S H T EST HUSH T EST HUSH T EST HUSH T EST HUSH Device a b...

Страница 46: ...10 to 90 Dimension W x H x D 62 6mm 62 6mm 18mm Weight 73 5 g Specification 1 Screen 2 Probe interface 3 Ba ery 4 Tamper bu on 5 Power switch A Tamper alarm B Enrollment C Signal strength D Ba ery le...

Страница 47: ...1 3 2 xxxx Device 1 A B C D E 2 4 3 5 4 I Signal Strength Test 5 II a b 1 2...

Страница 48: ...pping Support Enrolling method Power up remote ID QR code Standard battery life 5 years in work status being triggered 20 mes per day Power supply Battery powered Battery type CR123A 5 Typical voltage...

Страница 49: ...1 2 2 3 4 5 6 7 1 e f g d a b c 74 2 mm 200 7 mm OFF ON 13 14 I Signal Strength Test II 3 1 2 13 3 4 5 6 7 8 9 xxxx Device...

Страница 50: ...42526 2930313233 3435 38 39 40 43 44 45 Cut 10 11 12 14 16 18 28 29 30 42 43 44 45 46 1 2 3 4 5 6 7 8 9 101112131415161718 Masking Seal 6 top Masking Seal 6 bo om 20212223242526 2930313233 3435 38 39...

Страница 51: ...ery type CR123A 2 included Standard ba ery life 3 Years Low ba ery voltage 2 45 V Current Max current 24mA Quiescent current 25uA Bracket L shaped adapterincluded days of use Alarm Microwave triggered...

Страница 52: ...3 5m 0m 1m 1m 0m 1 2 3 1 3 4 xxxx Device I II Signal Strength Test 1 2 3 4 2 W C G L G L C 0 5m Side View 4 1 min 3 min WEAK INVERSE STRONG INVERSE 30 s DISARMED ARMED 5m 5m 0m 1m 0m 10m 10m 3 5 m...

Страница 53: ...t detec on performance table Description Product code 868 06 001 Helpdesk 27 0 87 159 7341 Test 3 I Check signal strength and align the posi oning line II Install the detector a With screw b With doub...

Страница 54: ...1 I II 2 3 4 a b xxxx 3 min Device Signal Strength Test Z X Y X...

Страница 55: ...WxHxD Sensor 40 5 mm 146 mm 40 9 mm Magne c S ck 30 5mm 146mm 40 9 mm Weight 247 g Applica on Scenario Outdoor IP66 1 Magnet 2 Sensor 3 Ba ery 4 Power switch 5 Tamper bu on 6 LED Indicator 7 External...

Страница 56: ...1 3 2 4 1 1 2 3 4 5 6 7 I II 2 3 4 xxxx 3 min Device Signal Strength Test 9 8 X X Y Z 3_PA3 25 SUS III INPUT2 INPUT1 COM...

Страница 57: ...ature 20 C to 60 C 4 F to 140 F Opera ng humidity 10 to 90 Dimension H W D Sensor 22 5 mm 103 mm 23 2 mm Magnet 13 mm 34 4 mm 11 4 mm Weight 60 g Transmission frequency 868 MHz RF range 800m Ba ery CR...

Страница 58: ...1 3 2 3 1 2 4 1 I II 2 3 4 a b xxxx Device Signal Strength Test 4 5 6 7 Magnet Test I II Start Tilt Test Start 3 min Shock Test Start III 8 4_KA3 25 5 5 24 5 mm Z X Y X...

Страница 59: ...the wall 3 Fix the wall moun ng plate to the junc on box with 2 screws Notes If you install the device with a gang box 75 mm width 75 mm length 46 mm depth the upper and lower holes will be applies I...

Страница 60: ......

Страница 61: ...the mounting template Remove the template from the wall 2 Align the protective shield with mounting template 3 Secure the mounting plate on the wall with 4 supplied screws according to the screw hole...

Страница 62: ......

Страница 63: ...the mounting template Remove the template from the wall 2 Align the protective shield with mounting template 3 Secure the mounting plate on the wall with 4 supplied screws according to the screw hole...

Страница 64: ......

Страница 65: ...the junction box to the hole chiseled on the wall 3 Fix the wall mounting plate to the junction box with 2 screws 4 Hook the indoor station to the wall mounting plate tightly by inserting the plate ho...

Страница 66: ......

Отзывы: