8.2.5
Properties
When you select uEye
®
Properties
from the main menu, a dialog box opens where you can set
the
uEye
camera parameters. Changes made to camera and image settings here will take effect
immediately.
When you close a camera in
uEye Demo
, the current settings are written to the Windows Registry.
They will be loaded the next time you open a camera of the same type. To save the settings to the
camera or to an ini file, select File
®
Save parameters
from the main menu. To load settings, select
the
Load parameters
option.
Camera
This tab provides parameters for settings the pixel clock frequency, frame rate and exposure time for
your
uEye
camera (see also Pixel Clock, Frame Rate and Exposure Time).
Figure 75: uEye properties - Camera
·
Camera peak bandwidth
Maximum required bandwidth in MB/sec (peak load). This value is displayed in red if the available
Gigabit Ethernet bandwidth is exceeded.
·
Camera average bandwidth
Required average bandwidth in MB/sec. This value is displayed in red if the available Gigabit
Ethernet bandwidth is exceeded.
The average bandwidth is calculated from the following data: Image size, image format, frame rate,
and interface-related protocol overhead.
·
Sensor (max. bandwidth)
Maximum data volume in Mpixels/sec created by the sensor.