 Connecting Magnetic Contacts and Panic Buttons to a Zone 

 

 

 

 

 

 

 

 

 

 

Tamper connection 

 

 

 

 

 

 

 

 

 

 

Programmable Outputs  

Outputs are used to trigger other devices, with a positive 12V. The output can be either set to pulse 

or latch.  

 

Definition: 

1.

 

Pulse  is  when  the  output  will  go  from  no  voltage  up  to  12V  and  with  no  intervention  goes 

back to no voltage. Like a spring if you compress it and then leave it alone it automatically 

uncompresses. 

2.

 

Latch is when the output will go from zero to 12V and stay there until something else tells it to 

go back to zero volts, like a light switch.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Output (805S Only) 

The serial connection outputs an IDS serial protocol that can communicate to any device which has the 

protocol implemented. The serial connector can also be used to upload and download settings via 

IDSwift2 and the IDS USB to Serial convertor.   

 

 

 

 

 

 

 

 

        Ground 

 

        Serial Connector   

 

 

 

        Rx  

 

 

 

 

 

 

 

 

 

 

        Tx 

 

 

 

 

 

 

 

 

           

Magnetic Contact 
(NC) 

Panic Button 
(NO) 

The  diagram  shows  a  magnetic  contact  (NC)  and  a  panic  button  (NO) 
connected to a zone  

3K3 

3K3 

LED connected to output 

Radio connected to output 

Содержание 805

Страница 1: ...Installer Training 805 Stock Code 860 1 B08 MN 805S Stock Code 860 1 0808M Training Manual s...

Страница 2: ...______________________________________________ 29 Adding General User Codes _________________________________________________________________________ 29 Adding a Maid s Code___________________________...

Страница 3: ...ry retains all program and event log data in the event of a total power failure Programmable loop response time for all zones global Up and downloadable using IDS windows based software Excellent prot...

Страница 4: ...Hardware Default Button Dialler Board Connectors Radio Tx Programmable Output 12V Keypad 16V AC Siren Neg Zones Connectors Serial Connector IDS 805 IDS 805s...

Страница 5: ...s exceeded this will take current away from the battery charging circuit and the battery may never fully charge Power supply to any radio transmitter While it may seem unnecessary to some in order to...

Страница 6: ...stor please test frequently Zones Devices that are connected to zones are divided into two categories normally open NO or normaly closed NC Some devices have both and the installer can select either d...

Страница 7: ...range which equals 3 3 Put the first two bands together which will be 33 4 The third band is red which is equal to 100 5 To get the value of the resistor multiply the first two digits 33 with the thir...

Страница 8: ...2 Latch is when the output will go from zero to 12V and stay there until something else tells it to go back to zero volts like a light switch Serial Output 805S Only The serial connection outputs an I...

Страница 9: ...progress of such communication To view the communication status proceed as follows 1 Hold down the 0 key until the keypad buzzer sounds twice 2 Press the 9 key The ARMED READY and AWAY LEDs will flash...

Страница 10: ...ng mode also known as installer mode To do this an installer code must be entered This code can be a four or six digit code By default 9999 Below is a description of the keys to be used when entering...

Страница 11: ...ue that will make the system do what is required or to exit A long beep will be heared if the value is acceptable 3 beeps if there is an error If correct the ready LED will flash showing that the loca...

Страница 12: ...as shown in the DEFAULT column in the programming list All user codes will also be defaulted and the master user code will become 1234 Same as a hardware reset 1 Will default the master user code to 1...

Страница 13: ...condition and sound the siren 5 Arm Disarm A violation of an Arm Disarm zone will cause the panel to arm or disarm depending on its current state The end of line resistor is required 6 Silent Priority...

Страница 14: ...ust be closed and the entry exit delay is operational 11 On On On All zones must be closed and the entry exit delay is operational 12 Off Off On All entry exit and follower zones can be open and the e...

Страница 15: ...m The ability to arm the system by holding the 1 key down until the systems begins to arm Entry Exit delay with arm zone When a zone is an arm disarm zone and a key switch or a remote receiver transmi...

Страница 16: ...n 0 Disable 1 Enable Location 16 Siren Toot on Arm and Disarm When the alarm is away armed the siren will sound once and when disarmed from the away armed state it will sound twice Value Siren toot on...

Страница 17: ...from opening a primary entry exit zone to a person having to entering a valid user code before the alarm is triggered Location 21 Hardware Reset Switch Enable Disable If this option is enabled the al...

Страница 18: ...put Explanation 22 Alarm 2 Pulse 2 Burglar alarm registered 23 Panic 1 Pulse 1 Panic triggered 24 Low Battery 0 Battery needs checking 25 Auto test 0 Panel does a test to the monitoring company 26 Dur...

Страница 19: ...oth phone numbers are joined to create a single number using pulse dialling 5 Yes Tone Single Both phone numbers are joined to create a single number using tone dialling Location 43 to 46 Primary Comm...

Страница 20: ...e of entering a phone number Number to be dialled 0 to get a line 4 second pause 08607051373 Location 48 49 50 51 52 53 54 55 56 57 58 59 60 61 Digits 10 15 10 8 6 10 7 10 5 1 3 7 7 0 NB Location 61 h...

Страница 21: ...est 130 131 Low Battery Restoral 113 114 Keypad Fire 132 133 Box Tamper 115 116 Keypad Medical Location 136 to 139 Installers Code The default Installers code is 9999 and should always be changed once...

Страница 22: ...rm Location 144 Trouble Display This location is a choice of displaying a trouble condition if a fault occurs for telephone line monitoring and a siren tamper Both or either can be displayed Value Tel...

Страница 23: ...s Yes Location 151 Dial Attempts 805 Only The number of times the system will try and dial if communication fails By default this is set to 4 Location 152 to 155 Secondary Communicator Account Code 80...

Страница 24: ...Telephone Line Monitoring Fail Output This will trigger an output if the telephone line goes missing Location 168 Telephone Line Monitoring Restore Output This triggers an output when the telephone l...

Страница 25: ...nificance of each lit zone LED The system will automatically exit the TROUBLE mode after ten seconds To clear the trouble condition press within 5 seconds of viewing To simply cancel the beeping witho...

Страница 26: ...in the away mode Ready Indicator Green The ready indicator comes on when the system is ready to arm Power Indicator Red Two functions 1 Show that the system has power 2 Show that a trouble condition e...

Страница 27: ...ode and if any zones have been enabled they will be bypassed automatically This will arm in the stay mode but all entry exit zones will work as if armed in the away mode If the power indicator is flas...

Страница 28: ...sabled Stay Go This function offers both away arm and stay arm functionality The system will arm in the stay mode but all entry exit zones will be active To arm in the Stay go mode 1 Press and hold th...

Страница 29: ...sarm the system before going into an alarm condition To activate buzz zones 1 Press and hold the 4 key 2 Press the zone number and continue until all have been selected 3 Press to exit Note If a zone...

Страница 30: ...seconds 2 Enter master code 1 2 3 4 3 User number 1 4 4 User code 4 4 3 2 Adding a Duress Code A duress code is a code that will disarm the alarm and activate a panic condition when used If system is...

Страница 31: ...o get to the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home Follower Zone A zone that may be...

Страница 32: ...users in stand alone mode 16 users when connected to the IDS805 3 LEDs for status information Programmed via an 8 way dip switch All arm or disarm actions logged by user Specifications Supply Voltage...

Страница 33: ...n LED Comes on for a second if a known remote transmitter signal is received Remains off if an unknown remote transmitter signal is received Power LED Comes on for a second if an unknown remote transm...

Страница 34: ...itter to a user code Step 1 Put dip switch 3 on 3 Step 2 Programming at the keypad To program a remote transmitter to a user code 1 Press and hold the key for 3 seconds 2 Enter the master code 3 Enter...

Страница 35: ...ch 4 on then 8 on 2 Press the button on the remote transmitter that you want as the panic button 3 Switch dip switch 8 off 4 Switch dip switch 4 off 4 8 Dip switch 8 goes on last but first off after p...

Страница 36: ...next when a button is pressed To set a relay to either pulse or toggle 1 Switch dip switches 5 6 7 on 2 Switch dip switch 8 on 3 Dip switch 1 on for relay 1 to pulse 1 off to toggle relay 1 and dip s...

Страница 37: ...wer is lost it will switch to normally closed To setup safe and secure mode 1 Switch dip switch 6 on 2 Switch dip switch 8 on 3 Select which relay by switching either dip switch 1 or 2 or both on 4 Sw...

Страница 38: ...Learning a Panic Remote To teach a remote as a panic remote 1 Switch dip switch 6 on 6 2 Press a button on the remote transmitter 3 Switch dip switch 6 off...