6-4)  WORKING LIMITS

Prolonged inactivity (machine stopped) in temperatures less than 5°C (5 degrees

centigrade) can cause damage or breakage to the pump, hoses, and to the parts in general. It is therefore advisable to 

completely empty the machine. Read the warning notice in section 5-2 of this manual and if more information is requi-

red contact the retailer or manufacturer.

6-5)  POSITIONING OF THE OPERATOR AND DANGER AREAS

The machine is equipped with a 10 metre long High Pressure hose so the operator never loses sight of the machine and 

the relevant electrical and hydraulic connections, he can

move around freely and wash within this area.

6-6)  SAFETY FEATURES AND WARNING INDICATIONS

The pressure washer is equipped with the following safety features:

A- PROTECTIVE AMMETER: it is an integrated safety feature of the power switch that turns off the pressure cleaner 

in case of electrical overload, automatically tripping the power

switch into the OFF position.

Whenever this safety feature is activated this sequence must be followed:

- remove the plug from the wall socket

- press the trigger on the pressure cleaner to release any residual pressure remaining

- wait for 10 minutes for the pressure washer to cool down

- disconnect the electric plug and verify that it complies with the instructions contained in

the paragraph “Connection and installation of the electricity supply,” checking the extension lead used.

- reconnect the electric plug and repeat the procedure for start up descibed in the aragragh, “initial activity and start-up”

GB

WARNING:

The pressure washer has an exhaust for the evacuation of exhaust fumes that is considered a DANGER AREA because 

it emits hot fumes from the combustion of diesel. DO NOT TOUCH the exhaust because it can be very hot and it is 

EXPRESSLY FORBIDDEN to cover the exhaust with objects, clothes, or any other items. Do not expose the face or 

any other part of the body to the exhaust fumes.

WARNING:

The pressure washer produces a jet of high pressure water from the nozzle at the end of the lance that is considered a 

DANGER AREA because it can produce serious damage due to the high force of the water.

IT IS EXPRESSLY FORBIDDEN

to direct the jet against people or parts of the body, animals or fragile objects. The failure to

observe this warning can cause serious injury or damage like cuts and lacerations. 

The manufacturer can not be held liable for any damage, accidents or injuries to people or

animals due to the disregard of this prohibition

Distributed by Australian Pump Industries (02) 8865 3500

 
                    NEVER direct spray jet at any surface that may contain asbestos material.

Содержание Stella 1000-100/11

Страница 1: ...GB Operator s Manual Distributed by Australian Pump Industries 02 8865 3500 From serial number 1121001 onwards...

Страница 2: ...ing the gun open Wait for steady pressure 2 Wind BY PASS valve down to lowest setting reduces flow to minimum 3 Turn thermostat to required STEAM setting 4 Do not release the gun trigger when working...

Страница 3: ...pag 42 5 2 Inactivity pag 42 5 3 Transport pag 43 5 4 Halding pag 43 5 5 Standard equipment pag 43 5 6 Installation and connection pag 43 5 7 Cleaning and disinfecting pag 45 5 8 Reinstallation and re...

Страница 4: ...7 9 Emergency stop pag 51 7 10 Resetting conditions pag 51 7 11 Storage operation pag 52 8 Maintenance pag 53 8 1 Regular maintenance pag 53 8 2 Extraordinary maintenance pag 54 8 3 Technical informat...

Страница 5: ...y starts from the date of purchase The valid date of purchase is that indicated on the receipted or invoice issued at the time the equipment is delivered by the retailer IDROBASE undertakes to repair...

Страница 6: ...of unauthorized personnel or persons who are not wearing suitable protective garments Although a suitable grip is provided with the lance the water pressure at the start of the discharge from the nozz...

Страница 7: ...t may cause serious damage to the high pressure pump WARNING Protective garments should be worm WARNING This manual must be read before using WARNING Only use recommended liquid detergents the use of...

Страница 8: ...ainless steel frame equipped with wheels and with a plate on which are fitted the motor pump regulating valve control panel and hoses The heating unit which produces hot water is composed of an electr...

Страница 9: ...common sense You should not use the machine if you experience any defects or damage that could compromise the original security the responsible for the installation the user or maitenance technician h...

Страница 10: ...chine TECNICAL DATA MODEL Pressure bar Flow rate l min Power Kw Temperature Max C Weight kg 1000 100 11 100 11 2 2 90 160 1000 200 15 200 15 5 5 80 165 OVERALL DIMENSIONS cm A B C 570 1130 890 4 TECHN...

Страница 11: ...carried out to conform to all local laws and regulations After having unpacked the machine make sure that the pressure washer is complete including all of the requested accessories 5 2 INACTIVITY Duri...

Страница 12: ...ile respecting the normal health and safety regula tions 5 4 HANDLING Always use a fork lift truck to move or handle the machine 5 5 STANDARD EQUIPMENT Check that the packaging contains the following...

Страница 13: ...must respond to the rating of the Stella 11 The Stella must be properly connected to an efficient grounded system matching and combined with a circuit breaker with a sensitivity of 30mA in A class 12...

Страница 14: ...is recommended that all parts which could be dangerous are rendered safe removing all of the electrical compo nents while conforming to current legislation regarding the scrapping of these materials...

Страница 15: ...AND USE GB 1 Do not leave the Stella for more than three continuous minutes in BY PASS 2 Do not leave the Stella in the TOTAL STOP position without the presence of the operator 3 Do not leave the Ste...

Страница 16: ...cool down disconnect the electric plug and verify that it complies with the instructions contained in the paragraph Connection and installation of the electricity supply checking the extension lead u...

Страница 17: ...t and outlet 6 7 PERSISTENT HAZARDS The pressure washer was designed to eliminate as much as possible any cause of danger when in use however RISK OF BURNS from the heating unit exhaust described in t...

Страница 18: ...STAGE position 18 Turn on the burner via the thermostat and position it at the desired temperature 19 During the washing operation with steam do never close the gun 20 The first step to turn off the...

Страница 19: ...e use of detergents or disinfectants it is useful to run the machine for a few minutes with clean water to rinse out the circuit WARNING Do not use the pressure washer to suck in any products containi...

Страница 20: ...the following sections 7 8 STOPPING OPERATION 1 When using a hot water machine run the pressure washer with cold water for a few minutes by turning the ther mostat to 0 C zero C 2 Completely close th...

Страница 21: ...nnot withstand very cold temperatures Do not leave the machine in an enviroment in which the temperature is less than 5 C In case of storage in a cold enviroment with a temperature less than 5 C first...

Страница 22: ...plugs are in a good state of repair Verify also that the water hose high pressure hose connections gun and lance are in excellent condition NB If one or more of these components are damaged do not us...

Страница 23: ...filter cup pump and nozzle Adjustment or replacement of the electrodes Clean the heater Check the tension in the drive belt Check the pump is securely fixed Check the motor is securely fixed Check th...

Страница 24: ...tch off the machine diassemble the nozzle and clean it 3 Check the water supply circuit 4 Check the positioning of the hose or replace it Pressure in the pump is above normal level but the pressure to...

Страница 25: ...d in this instruction manual For possible repairs seek advice from the manufacturer 10 2 SPARE PARTS The pressure washer comes delivered with this instruction manual with the spare parts booklet enclo...

Страница 26: ...y cutting the power cable It is recommended that the parts that can be dangerous are rendered safe for example remove all electrical parts while following current legislation regarding their disposal...

Страница 27: ...ack Blue Black Blue Black Black Nero Marrone Blu Gia llo Bianco 400V 50HZ Thermostat Nero Black P2 High pression pressure switch P1 Pump pressure switch Total stop board Motor Pump H V igniction trans...

Страница 28: ...er Caldaia Motore Motor Burner Black Nero Nero Black Marrone Brown Blu Blue Giallo Yellow Bianco White P2 Pres sostato A P Scheda total stop P1 Pres sostato pompa P2 High pression pressure switc h P1...

Страница 29: ...by relesing to the identification plato is in accordance with the following Directive 89 336 CEE Directive EMC Directive and subsequent emendaments 73 23 CEE Directive Llow Voltage Directive and subs...

Страница 30: ...30 NOTES Distributed by Australian Pump Industries 02 8865 3500...

Страница 31: ...31 NOTES Distributed by Australian Pump Industries 02 8865 3500...

Страница 32: ...ed firm n 9 190 IDRH 11 02 2005 UNI ES ISO 9001 2000 35010 BORGORICCO PD ITALIA Via Dell Industria 25 Tel 39 049 9335903 Fax 39 049 9335922 E mail idrobase idrobase com www idrobase com Distributed by...

Отзывы: