MSD-402 Command Guide
36
@GST / @SST
Saturation
Function
Getting
Setting
Format
@GST
@SST, ch_1, saturation_1 (, ch_2,
saturation_2
・・・
)
Return value
@GST, saturation_1, saturation_2,
saturation_3, saturation_4
@SST, ch_1, saturation_1 (, ch_2,
saturation_2
・・・
)
Parameter
saturation_1-4: Saturation
0 to 200 [Default]: 100
ch_1-4: Input channel
0 = All inputs, 1 = IN1 to 4 = IN5
Example
@GST
@GST,100,100,100,105
Getting saturations
IN4: 105%; Other input channels: 100%
。
@SST,4,105
@SST,4,105
Setting IN4 saturation to 105%
Completed normally.
Remarks
-
@GSU / @SSU
Black level
Function
Getting
Setting
Format
@GSU
@SSU, ch_1, setup_1 (, ch_2,
setup_2
・・・
)
Return value
@GSU, setup_1, setup_2, setup_3,
setup_4
@SSU, ch_1, setup_1 (, ch_2,
setup_2
・・・
)
Parameter
setup_1-4: Black level
-20 = -20
×
0.5 (-10.0 %) to +20 = +20
×
0.5 (+10.0 %)
[Default]:
±
0 =
±
0.0%
ch_1-4: Input channel
0 = All inputs, 1 = IN1 to 4 = IN4
Example
@GSU
@GSU,0,0,0,15
Getting black levels
I IN4: +7.5%; Other input channels: 0%.
@SSU,4,15
@SSU,4,15
Setting IN4 black level to +7.5%
Completed normally.
Remarks
-