MSD-402 Command Guide
80
@GSS
Input and output status
Parameter
*3 Format of audio input signals
Reply example
Format of audio input signal
LINEAR PCM 48kHz Linear PCM signal is input, and the sampling frequency
is replied.
LINEAR PCM 48kHz
(MULTI CHANNEL)
Multi channel linear PCM signal is input.
COMPRESSED
AUDIO
Compressed audio signal (such as Dolby Digital and
DTS) is input (The MSD does not recognize detailed
formats.
“COMPRESSED AUDIO” is sent to all
compressed audios).
NO SIGNAL
No video signal is input.
*4 HDCP authorization
Reply example
HDCP authorization
HDCP SUPPORT
Device with HDCP is connected.
HDCP NOT
SUPPORT
Device without HDCP is connected.
HDCP ERROR
Device with HDCP is connected, but the authorization
failed.
HDCP CHECK NOW Connection status of sink device was changed, and the
status is being checked.
MONITOR
DISCONNECT
Sink device is disconnected.
Cat6 LINK
DISCONNECT
Cat6 / Cat5e cable is disconnected.
(Only for OUT2)
Cat6 NO LINK
Cat6 / Cat5e cable is not connected.
(Only for OUT2)
UNCONNECTED
Sink device is not connected.
*5 Type of output signals
Reply
example
Type of output signals
Hxx
HDMI signal is output. xx stands for the color depth, 24 or 30.
D
DVI signal is input.
C
HDCP is being authenticated. No video is output.
N
No sink device is connected.
O
No twisted pair cable is connected.