HDC-UHD Series User Guide
52
9.4.1 Copying EDID
EDID of the sink device is loaded and registered to the HDC. The stored EDID can be treated as built-in
EDID by registering the EDID.
Menu
F01 to F03: Copied data 1 to Copied 3
WEB menu EDID SETTINGS
→
SINK DEVICE EDID COPY
Setting value
[Table 9.9] Setting values for copying EDID
Setting
Front
buttons
WEB browser
OUT1 [Default]
01
OUT1 COPY1 to 3
OUT2
02
OUT2 COPY1 to 3
OUT3
03
OUT3 COPY1 to 3
OUT4
04
OUT4 COPY1 to 3
OUT5
05
OUT5 COPY1 to 3
To copy EDID:
Step 1: Save the EDID of sink device to Copied data 1, 2, or 3. Menu number: [F01 to F03]
Step 2: Select the desired Copied data. Menu number: [F14 to F15] (P.57)
Step 3: Set EDID Resolution to “COPY (Copied EDID)”. Menu number: [F10 to F11] (P.53)
to
OUT 1
OUT 2
LCD
Copied EDID
EXTERNAL(External EDID)
Blu-ray player
Step (1)
Step (3)
Built-in EDID
Copied data
2
Copied data
1
Copied data
3
Step (2)
[Fig. 9.3] Copying EDID (Example: HDC-TR121UHD)
Note:
For daisy chain connection, the source device reads EDID of the extender (A) that is directly connected to
the source device. If multiple extenders are connected between source device and sink device, follow the
procedure below to copy the EDID of sink device.
To read EDID in daisy chain connection:
Step 1: Copy the EDID of the sink device to the extender (B).
Set EDID to “COPY (Copied EDID)” or “EXTERNAL (External EDID)”
Step 2: Copy the EDID of the extender (B) to the extender (A).
Set EDID to “COPY (Copied EDID)” or “EXTERNAL (External EDID)”
Laptop
Projector
HDC-TR121UHD
(A)
HDC-TR121UHD
(B)
[Fig. 9.4] Reading EDID in daisy chain connection