HDC-UHD Series Command Guide
46
@GPS
Power voltage
Getting
Command @GPS
Response @GPS, voltage, status
Parameter
voltage: Power voltage = Power voltage level x 1000
e.g.) 12.210 V: 12210
status: Power voltage status
0 = Normal, 1 = Abnormal
Getting
example
Command
Response
@GPS
@GPS,12210,0
Description Getting the power voltage
Voltage: 12.210 V; status: Normal
Remarks
-
@GST
Internal temperature
Getting
Command @GST
Response @GST, temp, status
Parameter
temp: Internal temperature value
The value of temperature x 100
e.g.) 38.75°C: 3875
status: Internal temperature status
0 = Normal, 1 = Abnormal
Getting
example
Command
Response
@GST
@GST,3425,0
Description Getting the internal temperature
Temperature: 34.25°C; status: Normal
Remarks
-
@GIV
Version
Getting
Command @GIV
Response @GIV, id, version
Parameter
id
: Model number
version : Firmware version
Getting
example
Command
Response
@GIV
@GIV,HDC-TR121UHD,1.00R0
Description Getting the product information
Model number: HDC-TR121UHD; Firmware version: 1.00R0
Remarks
-