IDI imaging tables are designed to provide excellent 

fluoroscopic imaging access with mobile C-arms. 

Whenever the table is used for procedures involving the 

use of a mobile C-arm, or any other equipment that 

produces ionizing radiation, all radiation safety standards 

and precautions should be applied, including but not 

limited to proper use of X-ray protective shielding for 

patients, operators and support personnel. 

WARNING! 

Radiation shields require careful handling and periodic 

testing for safe use. 

Test upon receipt and at regular intervals to insure 

shielding integrity. Test procedure and schedule to be the 

responsibility of the appropriate department of the facility 

where used. 

 

Содержание Aspect100T

Страница 1: ...Operator Manual Aspect 100T Made in the USA Aspect100T Mobile Fluoroscopic Table Operator Manual...

Страница 2: ...RD ALERTS 10 SAFETY INSTRUCTIONS 10 OPERATOR CONTROLS 19 EMERGENCY STOP SWITCH 20 EQUIPOTENTIAL TERMINAL 20 ELECTRIC SYSTEM 21 MAINTENANCE 24 USER REPLACEMENT ITEMS 25 TROUBLE SHOOTING 26 DISPOSAL OF...

Страница 3: ...op Low attenuation patient pad Standard Tabletop 61cm x 203cm 24in x 80in Imaging area 61cm x 157cm 24in x 62in Trendelenburg 15 Height range 71cm to 101cm 28in to 40in Patient capacity 204kg 450lbs T...

Страница 4: ...ties This equipment should only be installed in an area provided with the proper electrical power The owner is responsible for verifying continued compliance with all applicable regulations and standa...

Страница 5: ...lified technical personnel to repair those parts of equipment which are designated by the manufacturer as repairable For technical assistance call IDI at 978 829 0009 or send fax to 978 829 0027 Be pr...

Страница 6: ...se instructions can cause accidents resulting in serious personal injury or damage to equipment CD ROMs containing file copies of all relevant drawings BOMs and documentation are included with this ma...

Страница 7: ...rubber latex Single Use item This symbol when used in this manual indicates the potential of exposure to harmful x rays Be sure to read and comply with all warnings European Authorized Representative...

Страница 8: ...50Hz Duty Cycle 10 6 min hr Current Rating Less than 10 Amps Internally Battery Powered Environmental Operating Temperature Range 10 C to 40 C Operating Humidity Range 30 to 75 relative humidity nonc...

Страница 9: ...nt must be installed and used according to the manufacturer s instructions in order to avoid radio frequency interference If this equipment generates or receives interference Verify that the equipment...

Страница 10: ...battery backup Plug the power cord into a properly grounded hospital grade outlet The green indicator will illuminate The green indicator can be seen through the port in the large side cover The outle...

Страница 11: ...properly cleaned between patient use as it will inevitably come into contact with contaminants during procedures SAFETY HAZARDS Operators using this equipment should understand the safety issues emer...

Страница 12: ...has not been tested for use with high frequency surgical equipment cardiac defibrillators or cardiac defibrillator monitors WARNING If an antistatic path is required use the equipment on an antistatic...

Страница 13: ...n found marked on the equipment means Attention consult accompanying documentation WARNING Always safely position and secure patient on table WARNING Do not exceed patient weight of 450 pounds 204kg C...

Страница 14: ...operation CAUTION Do not sit on the table top at the head of the table CAUTION Do not place or store any containers or large items underneath the tabletop As the tabletop is descending contact with a...

Страница 15: ...IES CRESCENT FACE CUSHION supplied with some models Use this pad for patient comfort when the patient will be positioned face down Place a disposable cover over the pad LATEX Crescent Face Cushion Hea...

Страница 16: ...F THE TABLETOP OVER THE TOP SURFACE OF THE TABLETOP PHOTO OF STRAP ARRANGEMENT Patient Restraint Strap Set Standard Part Number C000 0328 Two straps one 3 wide and one 5 wide with hook loop fasteners...

Страница 17: ...pen latch to install to accessory rail or remove from accessory rail B Armboard pad C Pull trigger to rotate armboard to desired position D Hook loop patient straps Clamp on Rail Accessory Assembly A1...

Страница 18: ...al shields have hook fasteners that are engaged into the loop fasteners of the saddle Overlap shields as shown Step A Place the saddle with the loop fastener side up on the tabletop The adhesive dots...

Страница 19: ...ers that are engaged into the loop fasteners of the saddle Overlap shields as shown Step A Place the saddle with the loop fastener side up on the tabletop The adhesive dots may be applied to hold the...

Страница 20: ...produces ionizing radiation all radiation safety standards and precautions should be applied including but not limited to proper use of X ray protective shielding for patients operators and support p...

Страница 21: ...00 0054 plus label D100 731 FOOT CONTROL OPTIONAL The pair of pedals on the left move the tabletop up and down The pair of pedals on the right control the Trendelenburg motion Foot Control Part Number...

Страница 22: ...ctions the emergency stop control prohibits motion by removing power from all system components ACTIVATE Engage the emergency stop mode by pushing the button down RESET Restore the electrical function...

Страница 23: ...procedures may be in place for proper disposal or recycling For more information about batteries such as battery life production codes and disposal go to the Linak web site for disposal information S...

Страница 24: ...1 10 and 1 100 with water Alcohol generic Envirocide Disinfectant and Cleaner APPROVED AND TESTED GENERAL PURPOSE CLEANERS Simple Green cleaner CLEANING STEPS 1 Move the tabletop into the horizontal...

Страница 25: ...o one side at a time and allow to stand a few minutes 3 Scrub with a soft bristle scrub brush Do not let the solution dry before rinsing 4 Rinse with water and a damp cloth 5 Scrub and rinse again if...

Страница 26: ...roper tools ROUTINE MAINTENANCE Lubrication is not required however powdered graphite may be used on the lifting tube PERIODIC PERFORMANCE CHECKS Semiannually perform functional inspections of carbon...

Страница 27: ...p fasteners Simply pull pad up gently to remove New replacement pads are supplied with new self adhesive fasteners installed and new mating pieces for the tabletop Peel off old fasteners from tabletop...

Страница 28: ...power cord And or movement No power at the receptacle Check appropriate circuit breaker A missing or loose connection Inspect wires and at the control box connections A blown fuse Change fuse with sa...

Страница 29: ...components typically found in IDI products but varies with model and options COMPONENT ITEM RECYCLING GROUP Actuator Spindle and Motor Housing Cable Metal Steel and Copper Plastic Copper Control Box P...

Страница 30: ...responsible for payment of service travel time and expenses and all time on site that the service representative is required to wait for access to the Product whether or not the service is completed T...

Страница 31: ...authorized IDI corporate officer no IDI employee or IDI representative or any other party is authorized to make any warranty in addition to those made in this Agreement 8 Warranty Terms Subject to Ch...

Страница 32: ...ironment for the Covered Product iii damage caused by use of the Covered Product for purposes other than those for which it was designed iv damage caused by disasters such as fire flood wind earthquak...

Страница 33: ...tions of its Official Warranty from time to time The warranty terms and conditions and IDI s obligations under such will be determined based on the prevailing version of IDI s Official Warranty in eff...

Отзывы: