background image

0901039 Rev: C (05/01) 

Page 16 of 16 

',6&/$,0(5

Knight Inc. does not accept responsibility for the mishandling, misuse, or non-performance of the 
described items when used for purposes other than those specified in the instructions. For hazardous 
materials information consult label, MSDS, or Knight Inc. 

:$55$17<

All Knight controls and pump systems are warranted against defects in material and workmanship for a 
period of ONE year. All electronic control boards have a TWO year warranty. Warranty applies only to the 
replacement or repair of such parts when returned to factory with a Knight Return Authorization (KRA) 
number, freight prepaid, and found to be defective upon factory authorized inspection. Bearings and pump 
seals or rubber and synthetic rubber parts such as “O” rings, diaphragms, squeeze tubing, and gaskets 
are considered expendable and are not covered under warranty. Warranty does not cover liability resulting 
from performance of this equipment nor the labor to replace this equipment. Product abuse or misuse 
voids warranty. 

World Headquarters: 

20531 Crescent Bay Dr. 

Lake Forest, CA 

92630-8825 USA 

TEL: (949) 595-4800 
FAX: (949) 595-4801

Atlanta Branch: 

8111 Technology Dr. NE 

Covington, GA 

30014 USA 

TEL: (770) 787-9400 
FAX: (770) 787-1155

Toronto Branch: 

2880 Argentia Road, Unit 6 

Mississauga, Ontario 

L5N 7X8 Canada 

TEL: (905) 542-2333 
FAX: (905) 542-1536

London Branch: 

#15 Brunel Centre 

Newton Road, Crawley 

West Sussex UK RH102UB 

TEL: (44) 1293-615570 
FAX: (44) 1293-615585

Sydney Branch: 

Unit 28, 317-321 

Woodpark Rd., Smithfield 

NSW Australia 2164 

TEL: 61-29-725-2588 
FAX: 61-29-725-2025

Amsterdam Branch: 

Marssteden 68 

7547 TD Enschede 

The Netherlands 

TEL: 31-53-428-58-00 

FAX: 31-53-428-58-09 

.1,*+7 ,1&

  A Unit of IDEX Corporation 

Содержание Knight Trak II KTL-6503

Страница 1: ...Page 1 of 16 0901039 Rev C 05 01 Knight Trak II Instruction Manual ...

Страница 2: ...POB Wiring 8 Drawing LFP Wiring 9 Drawing Control Connections for Multilinking 10 The Signal Input Board SIB 11 Drawing SIB Connection 12 The Management Input Board LMIB 13 Network wiring Diagram 15 CAUTION Knight Trak II has high voltage connected to the transformer Always disconnect main power when servicing the unit ...

Страница 3: ...Page 3 of 16 0901039 Rev C 05 01 ...

Страница 4: ...nals to low voltage data signals 6 67 0 237 216 1 A Laundry Management Input Board LMIB which receives hot and cold water signals and other information relating to wash cycle tracking 2 A Low Level Alarm LLA which senses low chemical supplies and alerts washroom personnel 3 A full size 80 column printer which provides printed information 4 A Printer Terminal Module RM which provides external stora...

Страница 5: ...d connect signal wires from the signal source to the SIB Connect the SIB to the LFP Connecting the SIB to the LFP requires a three conductor shielded cable available from Knight Equipment Color coded connections on the LFP are marked to insure correct hookup Conduit is not necessary as the SIB transmits low voltage D C data signals 8 Connect the LFP to the POB Connecting the LFP to the POB require...

Страница 6: ... Board and connecting other end to a wall mount booster transformer and RM 6000 Please see diagram included in this manual for details For laptop computers connect the RM 6000 to the female jack on the LFP remote location See The Reporter Dispenser Network diagram included in this manual for more information on connecting modems to the network Please refer to the RM 6000 or WinReporter instruction...

Страница 7: ... the instructions provided with the system For flush mode to work correctly the flush terminals on the POB must be connected together with a jumper or to a flow sensor If this is not done a flush error will result and the system will be disabled To reset the system push the reset button on the lfp 7 Connect the 115 VAC or 230 VAC supply voltage to the system 8 Program the system using the LFP Deta...

Страница 8: ...0901039 Rev C 05 01 Page 8 of 16 ...

Страница 9: ...Page 9 of 16 0901039 Rev C 05 01 ...

Страница 10: ...0901039 Rev C 05 01 Page 10 of 16 ...

Страница 11: ...visions for split common connection some washmachine s have provisions for separate wash and rinse commons See the next page 5 Connect the color coded interface wire Knight part number 0300058 to the SIB with gray wire nuts Connect the other end to the Laundry Formula Programmer LFP mounted on the front of the machine Wires must be shielded and maximum wire length is 100 feet Color coded markings ...

Страница 12: ...0901039 Rev C 05 01 Page 12 of 16 ...

Страница 13: ...his signal is used to count the number of drains in a given wash cycle A drain solenoid or a drain track on a card reading machine are typical sources for the drain signal COLD WATER This signal is used to help track total cold water usage Connect to the cold water fill valve or relay HOT WATER This signal is used to help track total hot water usage Connect to the hot water fill valve or relay 0 1...

Страница 14: ...0901039 Rev C 05 01 Page 14 of 16 ...

Страница 15: ...N 0300058 X ONLY 3 CONDUCTOR NETWORK CABLE KNIGHT P N 0300058 ONLY BLACK TERMINAL BROWN TERMINAL MALE W O L F W O L F W O L F W O L F W O L F FLO W W O L F F LO W FLO W FLOW FLO W F LO W W O L F FLO W FLO W FLO W FLO W FLO W MALE FEMALE Over Multi Link WINREPORTER 04 02 01 CONNECT THE PLUG INTO THE JACK ON THE CIRCUIT BOARD IN ANY ONE OF THE MULTI LINKED DISPENSERS KCI 6000 or RM 6000 X LENGTH OF ...

Страница 16: ...ts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equipment Product abuse or misuse voids warranty World Headquarters 20531 Crescent Bay Dr Lake Forest CA 92630 8825 USA TEL 949 595 4800 FAX 949 595 4801 Atlanta Branch 8111...

Отзывы: