Idex Blagdon Pump X75 Скачать руководство пользователя страница 34

x75afvmdl7sm-rev0411 

Page 13 

SERVICE AND OPERATING MANUAL

X75 Aluminium  Flap Valve Pump

Design Level 7

II 2GD T5

See page 17 for 

ATEX ratings

ITEM

 NO. 

PART NUMBER   DESCRIPTION  

QTY.

1  

031.012.000  

SLEEVE & SPOOL SET  

1

2  

070.006.170  

BEARING  

2

3  

095.043.156  

BODY, AIR VALVE  

1

4  

095.073.001  

ASSEMBLY, PILOT VALVE  

1

4-A  

095.070.558  

BODY, PILOT VALVE  

1

4-B  

560.023.360  

O-RING (SPOOL)  

2

4-C  

560.033.360  

O-RING  

4

4-D  

675.037.080  

RETAINING RING  

1

4-E  

755.025.000  

SLEEVE, PILOT VALVE  

1

4-F  

775.026.000  

SPOOL, PILOT VALVE  

1

5  

114.002.156  

INTERMEDIATE  

1

6  

115.020.080  

BRACKET, FOOT  

2

7  

115.021.080  

BRACKET, FOOT  

2

8  

132.002.360  

BUMPER, DIAPHRAGM PLATE  

2

9  

132.014.358  

BUMPER, AIR VALVE  

2

10  

135.016.162  

BUSHING, THREADED,  

 

 

W/ O-RING 560.001.360  

2

11  

165.011.157  

CAP, END  

2

12  

170.012.330  

CAPSCREW,  

 

 

HEX HEAD 1/2-13 UNC X 2.00  

8

13  

170.023.330  

CAPSCREW, HEX HEAD  

4

14  

170.024.330  

CAPSCREW,  

 

 

HEX HEAD, 7/16-14 X 1  

8

15  

170.032.330  

CAPSCREW, HEX HEAD  

8

16  

170.045.330  

CAPSCREW HEX HEAD  

4

17  

170.066.330  

CAPSCREW,  

 

 

HEX, 1/2-13 X 2.25  

36

18  

172.001.330  

CAPSCREW, SOCKET  

12

19  

196.003.155  

CHAMBER, INNER  

2

20  

196.004.155  

CHAMBER, OUTER  

2

21  

286.018.354  

DIAPHRAGM  

2

 

286.018.357  

DIAPHRAGM  

2

 

286.018.360  

DIAPHRAGM  

2

 

286.018.365  

DIAPHRAGM  

2

22  

312.015.155  

ELBOW, SUCTION  

2

23  

312.016.155  

ELBOW, DISCHARGE  

2

24  

334.020.000  

FLANGE, FOLLOWER  

4

25  

338.008.360  

FLAP VALVE  

4

 

338.008.365  

FLAP VALVE  

4

 

338.011.354  

FLAP VALVE  

4

 

338.011.356  

FLAP VALVE  

4

 

338.011.357  

FLAP VALVE  

4

26  

360.010.425  

GASKET, END CAP  

2

27  

360.013.379  

GASKET, FLANGE  

4

 

360.013.384  

GASKET, FLANGE  

4

28  

360.014.379  

GASKET, FLANGE  

4

 

360.014.384  

GASKET, FLANGE  

4

29  

360.021.000  

GASKET  

4

Содержание Blagdon Pump X75

Страница 1: ...ve Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair...

Страница 2: ......

Страница 3: ...34 60 PSI 40 PSI 40 68 60 101 9 80 135 9 100 169 9 120 203 9 140 237 9 160 271 8 180 305 8 20 PSI Air Inlet Pressure 100 PSI 80 PSI Liters per minute CAPACITY 0 100 200 300 400 500 600 700 800 900 100...

Страница 4: ...Steel equal to or exceeding ASTM specification A743 for corrosion resistant iron chro mium iron chromium nickel and nickel based alloy castings for general applications Commonly referred to as 316 Sta...

Страница 5: ...x75mfvmdl2sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Страница 6: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Страница 7: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Страница 8: ...nd caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operati...

Страница 9: ...l the outer diameter of one diaphragm off the 8 capscrews NOTE One side only On the free diaphragm assembly use a 3 8 allenwrenchtoturntheassembly diaphragm platesandscrew loosefromtheshaft Oncetheass...

Страница 10: ...blems with the pilot valve can be corrected by replacing the o rings Always grease the spool prior to inserting it into the sleeve If the sleeve is removed from the body reinsertion must be at the cha...

Страница 11: ...LE CAUSES A Discharge hose or line plugged or discharge head requirement greater than air supply pressure Disconnect discharge line to check B Spool in air distribution valve not shifting Remove end c...

Страница 12: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Страница 13: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Страница 14: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Страница 15: ...330 Capscrew Hex Head 8 17 095 043 010 Body Valve 1 18 196 100 015 Chamber Inner 2 19 560 022 360 O Ring 2 20 170 045 330 Capscrew Hex Head 4 21 530 036 000 Muffler Exhaust 1 22 685 041 120 Rod Diaphr...

Страница 16: ...ischarge 2 59 518 045 010 Manifold 2 60 338 011 354 Flap Valve 4 338 011 356 Flap Valve 4 338 011 357 Flap Valve 4 338 008 360 Flap Valve 4 338 008 365 Flap Valve 4 61 570 002 360 4 570 002 365 4 62 1...

Страница 17: ...x75mfvmdl2sm rev0411 Page 15 USE WITH HDF4 M ONLY...

Страница 18: ...Technologies Ireland Ltd A Unit of IDEX Corporation R79 Shannon Co Clare IRELAND Certifies that Air Operated Double Diaphragm Pump B and X Series comply with the European Community Directive 2006 42...

Страница 19: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...

Страница 20: ...e Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair D...

Страница 21: ......

Страница 22: ...ed air II 2GD T5 See page 17 for ATEX ratings 10 0 20 30 40 50 60 70 80 90 20 0 40 60 80 100 120 140 160 180 200 220 240 260 20 34 40 68 60 101 9 80 135 9 100 169 9 100 PSI 80 PSI 60 PSI 40 PSI 20 PSI...

Страница 23: ...Neoprene R Santoprene H Hytrel P Polyurethane Diaphragms B Nitrile R Santoprene N Neoprene Maximum delivery 998 ltrs min Max working pressure 8 6 bar Max solid particle size 75mm Air inlet 1 2 NPT Te...

Страница 24: ...x75afvmdl7sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Страница 25: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Страница 26: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Страница 27: ...s of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operation An...

Страница 28: ...nutsandelbows Whenthetopsuctionelbows areremoved thevalveandseatareconnectedasanassembly Whenthebottomdischarge elbowsareremoved thevalveandseatstaywiththeouterchamber Visualinspectionand cleaning is...

Страница 29: ...aining outer chamber on the open end and tighten down the securing nuts gradually and evenly on both sides Caution should be used while reassembling Flap valves The valves are designed for some preloa...

Страница 30: ...not shifting Remove end cap and check spool must slide freely C Diaphragm ruptured Air will escape out discharge line in this case D Blockage in diaphragm chamber preventing movement Shut off air supp...

Страница 31: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Страница 32: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Страница 33: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Страница 34: ...W O RING 560 001 360 2 11 165 011 157 CAP END 2 12 170 012 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8 13 170 023 330 CAPSCREW HEX HEAD 4 14 170 024 330 CAPSCREW HEX HEAD 7 16 14 X 1 8 15 170 032 330 CA...

Страница 35: ...360 O RING 2 40 570 002 360 PAD HINGE 4 570 002 365 PAD HINGE 4 41 570 012 371 PAD WEAR 2 42 612 014 000 PLATE DIAPHRAGM 2 43 612 015 156 PLATE OUTER DIAPHRAGM 2 44 618 003 330 PLUG PIPE 1 4 2 45 618...

Страница 36: ...5 USE WITH HDF4 M ONLY 32 21 20 22 29 19 30 4 A 4 D 31 3 16 4 F 4 E 48 10 37 46 14 34 28 35 53 47 40 50 27 52 50 51 25 33 23 24 56 17 6 4 B 4 C 15 11 8 58 42 59 36 5 26 9 38 1 45 7 39 54 12 17 55 44 2...

Страница 37: ...X Corporation R79 Shannon Co Clare Ireland Certifies that Air Operated Double Diaphragm Pump Series B75 X75 AVB75 AVX75 and Pulsation Dampener models PD25M PD40M PD50M PD80M comply with comply with th...

Страница 38: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...