REASSEMBLY

All procedures for reassembling the pump are the reverse of the previous instructions 

with further instructions as shown:
1.  The  diaphragm  assemblies  are  to  be  installed  with  the  natural  bulge  outward 

or  toward  the  head  of  the  center  screw.  Make  sure  both  plates  are  installed  with 

outer radii against the diaphragm.  After all components are in position in a vise and 

hand tight, set a torque wrench for 480 inch pounds (40 ft. pounds) (54.23 Newton 

meters) or, 600 inch pounds (50 ft. pounds) (67.79 Newton meters) for Santoprene, 

using  a  (3/8")  allen  head  socket.  After  each  diaphragm  sub  assembly  has  been  

completed, thread one assembly into the shaft (held near the middle in a vise having 

soft jaws to protect the finish) making sure the stainless steel washer is in place on the 

capscrew. 

  Make sure 1/4"-20 mounting screw has been removed and that the bumper (Item 

#19 on drawing) is in place in the shaft.

  Install this sub assembly into the pump and secure by placing the outer chamber 

housing and capscrews on the end with the diaphragm. This will hold the assembly 

in place while the opposite side is installed. Make sure the last diaphragm assembly 

is  torqued  to  30  ft.  lbs.  (40.67  Newton  meters)  before  placing  the  outer  diaphragm 

over the capscrews. If the holes in the diaphragm flange do not line up with the holes 

in  the  chamber  flange,  turn  the  diaphragm  assembly  in  the  direction  of  tightening 

to  align  the  holes  so  that  the  capscrews  can  be  inserted. This  final  torquing  of  the 

last  diaphragm  assembly  will  lock  the  two  diaphragm  assemblies  together.    Place 

remaining  outer  chamber  on  the  open  end  and  tighten  down  the  securing  nuts  

gradually and evenly on both sides. 

  Caution should be used while reassembling Flap valves. The valves are designed 

for some preload over the retainer hinge pad. This is done to insure proper face contact 

with the seat. After all  parts are in place, tighten the lock nuts down on the assembly 

to the point where visual inspection shows that seat and valve face mate without gap. 

This is important for dry prime. However, after priming action has started, valves will 

function due to differential pressure without concern or trouble.

PILOT VALVE

  The pilot valve assembly is accessed by removing the main air distribution valve 

body from the pump and lifting the pilot valve body out of the intermediate housing.

  Most problems with the pilot valve can be corrected by replacing the o-rings. Always 

grease the spool prior to inserting it into the sleeve. If the sleeve is removed from the 

body, reinsertion must be at the chamfered side. Grease the o-rings to slide the sleeve 

into the valve body. Securely insert the retaining ring around the sleeve. When reinserting 

the pilot valve, push both plungers (located inside the intermediate bracket) out of the 

path of the pilot valve spool ends to avoid damage.

PILOT VALVE ACTUATOR

  Bushings for the pilot valve actuators are threaded into the intermediate bracket 

from the outside. The plunger may be removed for inspection or replacement. First 

remove the air distribution valve body and the pilot valve body from the pump. The 

plungers  can  be  located  by  looking  into  the  intermediate.  It  may  be  necessary  to 

use a fine piece of wire to pull them out. The bushing can be turned out through the  

inner chamber by removing the outer chamber assembly. Replace the bushings if pins 

have bent.

Содержание Blagdon Pump X75

Страница 1: ...ve Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair...

Страница 2: ......

Страница 3: ...34 60 PSI 40 PSI 40 68 60 101 9 80 135 9 100 169 9 120 203 9 140 237 9 160 271 8 180 305 8 20 PSI Air Inlet Pressure 100 PSI 80 PSI Liters per minute CAPACITY 0 100 200 300 400 500 600 700 800 900 100...

Страница 4: ...Steel equal to or exceeding ASTM specification A743 for corrosion resistant iron chro mium iron chromium nickel and nickel based alloy castings for general applications Commonly referred to as 316 Sta...

Страница 5: ...x75mfvmdl2sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Страница 6: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Страница 7: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Страница 8: ...nd caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operati...

Страница 9: ...l the outer diameter of one diaphragm off the 8 capscrews NOTE One side only On the free diaphragm assembly use a 3 8 allenwrenchtoturntheassembly diaphragm platesandscrew loosefromtheshaft Oncetheass...

Страница 10: ...blems with the pilot valve can be corrected by replacing the o rings Always grease the spool prior to inserting it into the sleeve If the sleeve is removed from the body reinsertion must be at the cha...

Страница 11: ...LE CAUSES A Discharge hose or line plugged or discharge head requirement greater than air supply pressure Disconnect discharge line to check B Spool in air distribution valve not shifting Remove end c...

Страница 12: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Страница 13: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Страница 14: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Страница 15: ...330 Capscrew Hex Head 8 17 095 043 010 Body Valve 1 18 196 100 015 Chamber Inner 2 19 560 022 360 O Ring 2 20 170 045 330 Capscrew Hex Head 4 21 530 036 000 Muffler Exhaust 1 22 685 041 120 Rod Diaphr...

Страница 16: ...ischarge 2 59 518 045 010 Manifold 2 60 338 011 354 Flap Valve 4 338 011 356 Flap Valve 4 338 011 357 Flap Valve 4 338 008 360 Flap Valve 4 338 008 365 Flap Valve 4 61 570 002 360 4 570 002 365 4 62 1...

Страница 17: ...x75mfvmdl2sm rev0411 Page 15 USE WITH HDF4 M ONLY...

Страница 18: ...Technologies Ireland Ltd A Unit of IDEX Corporation R79 Shannon Co Clare IRELAND Certifies that Air Operated Double Diaphragm Pump B and X Series comply with the European Community Directive 2006 42...

Страница 19: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...

Страница 20: ...e Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair D...

Страница 21: ......

Страница 22: ...ed air II 2GD T5 See page 17 for ATEX ratings 10 0 20 30 40 50 60 70 80 90 20 0 40 60 80 100 120 140 160 180 200 220 240 260 20 34 40 68 60 101 9 80 135 9 100 169 9 100 PSI 80 PSI 60 PSI 40 PSI 20 PSI...

Страница 23: ...Neoprene R Santoprene H Hytrel P Polyurethane Diaphragms B Nitrile R Santoprene N Neoprene Maximum delivery 998 ltrs min Max working pressure 8 6 bar Max solid particle size 75mm Air inlet 1 2 NPT Te...

Страница 24: ...x75afvmdl7sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Страница 25: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Страница 26: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Страница 27: ...s of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operation An...

Страница 28: ...nutsandelbows Whenthetopsuctionelbows areremoved thevalveandseatareconnectedasanassembly Whenthebottomdischarge elbowsareremoved thevalveandseatstaywiththeouterchamber Visualinspectionand cleaning is...

Страница 29: ...aining outer chamber on the open end and tighten down the securing nuts gradually and evenly on both sides Caution should be used while reassembling Flap valves The valves are designed for some preloa...

Страница 30: ...not shifting Remove end cap and check spool must slide freely C Diaphragm ruptured Air will escape out discharge line in this case D Blockage in diaphragm chamber preventing movement Shut off air supp...

Страница 31: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Страница 32: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Страница 33: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Страница 34: ...W O RING 560 001 360 2 11 165 011 157 CAP END 2 12 170 012 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8 13 170 023 330 CAPSCREW HEX HEAD 4 14 170 024 330 CAPSCREW HEX HEAD 7 16 14 X 1 8 15 170 032 330 CA...

Страница 35: ...360 O RING 2 40 570 002 360 PAD HINGE 4 570 002 365 PAD HINGE 4 41 570 012 371 PAD WEAR 2 42 612 014 000 PLATE DIAPHRAGM 2 43 612 015 156 PLATE OUTER DIAPHRAGM 2 44 618 003 330 PLUG PIPE 1 4 2 45 618...

Страница 36: ...5 USE WITH HDF4 M ONLY 32 21 20 22 29 19 30 4 A 4 D 31 3 16 4 F 4 E 48 10 37 46 14 34 28 35 53 47 40 50 27 52 50 51 25 33 23 24 56 17 6 4 B 4 C 15 11 8 58 42 59 36 5 26 9 38 1 45 7 39 54 12 17 55 44 2...

Страница 37: ...X Corporation R79 Shannon Co Clare Ireland Certifies that Air Operated Double Diaphragm Pump Series B75 X75 AVB75 AVX75 and Pulsation Dampener models PD25M PD40M PD50M PD80M comply with comply with th...

Страница 38: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...

Отзывы: