PRINCIPLE OF PUMP OPERATION

This flap swing check valve pump is powered by compressed air and is a 1:1 pressure 

ratio design. It alternately pressurizes the inner side of one diaphragm chamber, while 

simultaneously exhausting the other inner chamber. This causes the diaphragms, which 

are connected by a common rod, to move endwise. Air pressure is applied over the 

entire surface of the diaphragm, while liquid is discharged from the opposite side. The 

diaphragm operates under a balanced condition during the discharge stroke, which 

allows the unit to be operated at discharge heads over 200 feet (61 meters) of water 

head.

Since the diaphragms are connected by a common rod, secured by plates to the 

center of the diaphragms, one diaphragm performs the discharge stroke, while the other 

is pulled to perform the suction stroke in the opposite chamber.

For maximum diaphragm life, keep the pump as close to the liquid being pumped as 

possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may require 

a back pressure regulating device. This will maximize diaphragm life.

Alternate  pressuring  and  exhausting  of  the  diaphragm  chamber  is  performed  by 

means of an externally mounted, pilot operated, four-way spool type air distribution 

valve. When the spool shifts to one end of the valve body, inlet air pressure is applied to 

one diaphragm chamber and the other diaphragm chamber exhausts. When the spool 

shifts to the opposite end of the valve body, the porting of chambers is reversed. The air 

distribution valve spool is moved by an internal pilot valve which alternately pressurizes 

one side of the air distribution valve spool, while exhausting the other side. The pilot 

valve is shifted at each end of the diaphragm stroke by the diaphragm plate coming in 

contact with the end of the pilot valve spool. This pushes it into position for shifting of 

the air distribution valve.

The chambers are manifolded together with a suction and discharge check valve for 

each chamber, maintaining flow in one direction through the pump.

INSTALLATION & START-UP

Locate the pump as close to the product being pumped as possible, keeping suction 

line length and number of fittings to a minimum. Do not reduce line size.

For installations of rigid piping, short flexible sections of hose should be installed 

between pump and piping. This reduces vibration and strain to the piping system. A 

pulsation dampener is recommended to further reduce pulsation in flow.

This pump was tested at the factory prior to shipment and is ready for operation. It is 

completely self-priming from a dry start for suction lifts of 20 feet (6.096 meters) or less. 

For suction lifts exceeding 20 feet of liquid, fill the chambers with liquid prior to priming.

AIR SUPPLY

Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet 

to an air supply of sufficient capacity and pressure required for desired performance. 

When the air line is solid piping, use a short length of flexible hose (not less than 3/4" 

(19mm) in diameter) between pump and piping to eliminate strain to pipes.

AIR INLET & PRIMING

For start-up, open an air valve approximately 1/2" to 3/4" turn. After the unit primes, 

an air valve can be opened to increase flow as desired. If opening the valve increases 

cycling rate, but does not increase flow rate, cavitation has occurred, and the valve 

should be closed slightly.

For the most efficient use of compressed air and the longest diaphragm life, throttle 

the air inlet to the lowest cycling rate that does not reduce flow.

SERVICE AND OPERATING MANUAL

II 2GD T5

See page 17 for 

ATEX ratings

X75 Aluminium Flap Valve Pump

Design Level 7

Содержание Blagdon Pump X75

Страница 1: ...ve Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair...

Страница 2: ......

Страница 3: ...34 60 PSI 40 PSI 40 68 60 101 9 80 135 9 100 169 9 120 203 9 140 237 9 160 271 8 180 305 8 20 PSI Air Inlet Pressure 100 PSI 80 PSI Liters per minute CAPACITY 0 100 200 300 400 500 600 700 800 900 100...

Страница 4: ...Steel equal to or exceeding ASTM specification A743 for corrosion resistant iron chro mium iron chromium nickel and nickel based alloy castings for general applications Commonly referred to as 316 Sta...

Страница 5: ...x75mfvmdl2sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Страница 6: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Страница 7: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Страница 8: ...nd caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operati...

Страница 9: ...l the outer diameter of one diaphragm off the 8 capscrews NOTE One side only On the free diaphragm assembly use a 3 8 allenwrenchtoturntheassembly diaphragm platesandscrew loosefromtheshaft Oncetheass...

Страница 10: ...blems with the pilot valve can be corrected by replacing the o rings Always grease the spool prior to inserting it into the sleeve If the sleeve is removed from the body reinsertion must be at the cha...

Страница 11: ...LE CAUSES A Discharge hose or line plugged or discharge head requirement greater than air supply pressure Disconnect discharge line to check B Spool in air distribution valve not shifting Remove end c...

Страница 12: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Страница 13: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Страница 14: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Страница 15: ...330 Capscrew Hex Head 8 17 095 043 010 Body Valve 1 18 196 100 015 Chamber Inner 2 19 560 022 360 O Ring 2 20 170 045 330 Capscrew Hex Head 4 21 530 036 000 Muffler Exhaust 1 22 685 041 120 Rod Diaphr...

Страница 16: ...ischarge 2 59 518 045 010 Manifold 2 60 338 011 354 Flap Valve 4 338 011 356 Flap Valve 4 338 011 357 Flap Valve 4 338 008 360 Flap Valve 4 338 008 365 Flap Valve 4 61 570 002 360 4 570 002 365 4 62 1...

Страница 17: ...x75mfvmdl2sm rev0411 Page 15 USE WITH HDF4 M ONLY...

Страница 18: ...Technologies Ireland Ltd A Unit of IDEX Corporation R79 Shannon Co Clare IRELAND Certifies that Air Operated Double Diaphragm Pump B and X Series comply with the European Community Directive 2006 42...

Страница 19: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...

Страница 20: ...e Actuator 8 Service Instructions Troubleshooting 9 Warranty 9 Grounding The Pump 10 Important Safety Information 11 Recycling 11 Material Codes 12 Composite Repair Parts List 13 14 Composite Repair D...

Страница 21: ......

Страница 22: ...ed air II 2GD T5 See page 17 for ATEX ratings 10 0 20 30 40 50 60 70 80 90 20 0 40 60 80 100 120 140 160 180 200 220 240 260 20 34 40 68 60 101 9 80 135 9 100 169 9 100 PSI 80 PSI 60 PSI 40 PSI 20 PSI...

Страница 23: ...Neoprene R Santoprene H Hytrel P Polyurethane Diaphragms B Nitrile R Santoprene N Neoprene Maximum delivery 998 ltrs min Max working pressure 8 6 bar Max solid particle size 75mm Air inlet 1 2 NPT Te...

Страница 24: ...x75afvmdl7sm rev0411 Page 3 Dimensions Dimensions are 1 8 Figures in parenthesis millimeters...

Страница 25: ...d at each end of the diaphragm stroke by the diaphragm plate coming in contact with the end of the pilot valve spool This pushes it into position for shifting of the air distribution valve The chamber...

Страница 26: ...ATION GUIDE Bottom Discharge Flap Valve Unit The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure CAUTION Available from Dist...

Страница 27: ...s of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freely to allow for proper pump operation An...

Страница 28: ...nutsandelbows Whenthetopsuctionelbows areremoved thevalveandseatareconnectedasanassembly Whenthebottomdischarge elbowsareremoved thevalveandseatstaywiththeouterchamber Visualinspectionand cleaning is...

Страница 29: ...aining outer chamber on the open end and tighten down the securing nuts gradually and evenly on both sides Caution should be used while reassembling Flap valves The valves are designed for some preloa...

Страница 30: ...not shifting Remove end cap and check spool must slide freely C Diaphragm ruptured Air will escape out discharge line in this case D Blockage in diaphragm chamber preventing movement Shut off air supp...

Страница 31: ...gnized code having juristiction over specific installations This 8 foot long 244 centimeters Ground Strap part number 920 025 000 can be ordered as a service item To reduce the risk of static electric...

Страница 32: ...les and loud noise hazards Wear ear and eye protection WARNING In the event of diaphragm rupture pumped material may enter the air end of the pump and be discharged into the atmosphere If pumping a pr...

Страница 33: ...ded BLUE 365 Neoprene Rubber Color Coded GREEN 366 Food Grade Nitrile Color White 368 Food Grade EPDM Color Gray 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 F...

Страница 34: ...W O RING 560 001 360 2 11 165 011 157 CAP END 2 12 170 012 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8 13 170 023 330 CAPSCREW HEX HEAD 4 14 170 024 330 CAPSCREW HEX HEAD 7 16 14 X 1 8 15 170 032 330 CA...

Страница 35: ...360 O RING 2 40 570 002 360 PAD HINGE 4 570 002 365 PAD HINGE 4 41 570 012 371 PAD WEAR 2 42 612 014 000 PLATE DIAPHRAGM 2 43 612 015 156 PLATE OUTER DIAPHRAGM 2 44 618 003 330 PLUG PIPE 1 4 2 45 618...

Страница 36: ...5 USE WITH HDF4 M ONLY 32 21 20 22 29 19 30 4 A 4 D 31 3 16 4 F 4 E 48 10 37 46 14 34 28 35 53 47 40 50 27 52 50 51 25 33 23 24 56 17 6 4 B 4 C 15 11 8 58 42 59 36 5 26 9 38 1 45 7 39 54 12 17 55 44 2...

Страница 37: ...X Corporation R79 Shannon Co Clare Ireland Certifies that Air Operated Double Diaphragm Pump Series B75 X75 AVB75 AVX75 and Pulsation Dampener models PD25M PD40M PD50M PD80M comply with comply with th...

Страница 38: ...ITLE 27 MAY 2010 AODD Pumps Equipped with Aluminium Type Examination Certificate KEMA 09ATEX0072 X AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X K...