background image

B-1906-1(0)

INSTRUCTION SHEET - HS6E Series 

Solenoid Type Safety Switch

( 2 / 6 )

2016.08

4

Precautions for Operation

For Mounting

• Do not apply an excessive shock to the safety switch when opening or closing the 

door.

 

A shock to the safety switch exceeding 1,000m/s

2

 may cause failure.

• Provide a door guide, and ensure that force is applied on the safety switch only in 

the actuator insertion direction.

• Do not pull the actuator while it is locked. Also, regardless of door types, do not use 

the safety switch as a door lock. Install a separate lock as shown in section 3.

• Entry of foreign objects in the actuator entry slot may affect the mechanism of the 

switch and cause a breakdown. If the operating atmosphere is contaminated, use a 

protective cover to prevent the entry of foreign objects into the switch through the 

actuator entry slots. 

• Make sure to install the product  in a safe place out of reach. Make sure to conduct a 

proper risk assessment evaluation before using the product, and use a shield or a 

cover to protect the product if need be. 

• While the solenoid is energized, the switch temperature rises approx-

imately 35°C above the ambient temperature (to approximately 85°C 

while the ambient temperature is 50°C). Keep hands off to prevent 

burns. If cables come into contact with the switch, use heat-resistant 

cables.

The Adjustable (vertical/horizontal) Actuator

• Using the angle adjustment screw (M3 hexagon socket set screw), the actuator 

angle can be adjusted up to 20°(refer to dimensions).

• The larger the actuator angle, the smaller the applicable radius of the door swing.  

After installing the actuator, open the door. Then adjust the actuator angle so that  he 

actuator enters the entry slot of the safety switch properly. 

  

• After adjusting the actuator angle, apply loctite or the like on the adjustment screw to 

prevent loosening. Use screw locking agent that is compatible with the base 

material.

     Base : PA66 (66 nylon) of glass reinforced grade
     Angle adjustment screws : stainless steel

Installing the Safety Switch and Actuator

• When installing the actuator, position the 

actuator using the actuator stop (for 

positioning the entry slot center and 

mounting reference position).

• As shown on the right, the mounting 

reference position of the actuator when 

inserted in the safety switch is where the 

actuator stop touches the actuator.

• Install a door stop as shown on the right 

to protect the safety switch and actuator 

against excessive force. Do not use the 

safety switch as a door stop, otherewise 

the safety switch will be damaged.

0.8mm

Safety Switch

Latch

Actuator Stop

HS9Z-A61

Actuator

Door Stop

Mounting

Reference

Door Stop

• After removing the actuator stop, ensure that the actuator is installed within the 

tolerances shown below.

   From  he entry slot center of the safety switch (*5, 6) : ±1.0mm  
  The gap between the actuator shoulder and the safety switch surface (*7)
    

HS9Z-A61/-A62/-A65/-A66 : 1.9mm or shorter

    

HS9Z-A62S : 1.3mm or shorter

• To ensure correct operation, it is recommended to fasten the door using a latch to 

achieve the above tolerance values.

• Make sure the actuator can be inserted into the entry slot without any issue.
• Perform operation test before starting operation in order to confirm the open/close 

operation of contacts and locking/unlocking operation.

• When the actuator is pulled while locked in the safety switch, the actuator moves 

within the range shown below.

    

HS9Z-A61/-A62/-A65/-A66 : 4.1mm maximum from the safety switch surface

    

HS9Z-A62S : 3.5mm maximum from the safety switch surface

  The open/close status of the contacts are maintained within the range.When a gap is 

caused because of actuator relocation, make sure that the gap does not lead to new 

risks.

±1.0mm

(*6)

±1.0mm

(*5)

Entry

Direction

1.9mm(

*7)

When using HS9Z-A61

Safety Switch

Surface

Minimum Radius of Hinged Door

• When using the safety switch for a hinged door, the minimum radius of the applica-

ble door is shown in the following figures.

When the center of the hinged 

door is

 

on the extension line of the 

actuator

 

mounting surfase.

When the center of the hinged 

door is

 

on  he extension line of 

the contact surface

 

of actuator 

and safety switch.

HS9Z-A62/-A62S

R1

230mm

70mm

(Horizontal Swing)

R2

230mm

70mm

(Vertical Swing)

R3

160mm

50mm

(Horizontal Swing)

R4

160mm

50mm

(Vertical Swing)

Minimum Radius

HS9Z-A65/-A66

CAUTION

The values shown above are based on the condition that the 

actuator enters and exits the actuator entry slot smoothly 

when the door is closed or opened. 
Since there may be devia ion or dislocation of the hinged 

door, make sure of correct operation in the actual applica-

tion before installation.
When inserting an actuator into the slot, make sure to 

arrange the    shapes in the same direction, as shown on 

the right.

R3

Minimum

Radius

Door

Hinge

Door

Hinge

Door

Hinge

Door

Hinge

R4

Minimum

Radius

Minimum

Radius

R1

Minimum

Radius

R2

Recommended Screw Tightening Torque

Name or Use

For mounting the safety switch ( M4 screw ) *8

For mounting the actuator ( M4 screw ) *8

Screw Tightening Torque

1.0 to 1 5 N•m

1.0 to 1 5 N•m

HS9Z-A61, HS9Z-A62, HS9Z-A62S ACTUATOR

• When there is a displacement of safety switch and actuator, the actuator may hit the 

entry lot of safety switch hardly, thus damaging the entry slot and actuator. The 

rubber cushions on the HS9Z actuator prevent the actuator from damaging the entry 

slit by absorbing the shock with movement flexibility. Do not, however, exert exces-

sive shocks, otherwise the failure of safety switch may be caused.

• The rubber cushions may deteriorate depending on the operatiing environment and 

conditions. Immediately replace the deformed or crasked rubber cushions with new 

ones. 

CAUTION

*8  When  he torque is not enough to recommended screw tightening torque, make 

sure that  he screw do not become loose by using adhesive sealants etc. to 

keep right operation and mounting positioning.

Mounting HS9Z-A62S actuator

Using two M4 screws and plate, fasten the 

actuator securely on the door.
Plate has directionality. Do not lose the 

plate. The actuator may fall off from the 

door if there is no plate, and the actuator 

does not properly.

The tensile strength of the HS9Z-A62 

actuator is 100N. If an excessive tensile 

force is applied, the actuator may fall off 

the door. When a tensile force exceeding 100N is expected, use the HS9S-A62S 

actuator with a plate.

Rubber Cushion

Plate(supplied)

M4 Screw

Door

M4 Mountion holes

3

Mounting Examples

(Examples of Mounting on Sliding Doors)

(Examples of Mounting on Hinged Doors)

Door

Door Stop

HS9Z-A62S

Actuator

HS9Z-A61

Actuator

Latch

HS6E

Safety Switch

• Install the interlock switch on the immovable machine or guard, and install the 

actuator on the movable door.  Do not install both interlock switch and actuator on 

the

 

movable door, otherwise the angle of insertion of the actuator to the safety switch 

may become inappropriate, and failure will occur.

Содержание HS6E Series

Страница 1: ...y or death Caution notices are used where inattention might cause personal injury or damage to equipment INSTRUCTION SHEET Original Instructions Solenoid Type Safety Switch HS6E Series S A F E T Y P R E C A U T I O N S CAUTION WARNING In order to verify if the product you are interested in is certified with the S mark please check the following section on our website List of type numbers certified...

Страница 2: ...the safety switch the actuator moves within the range shown below HS9Z A61 A62 A65 A66 4 1mm maximum from the safety switch surface HS9Z A62S 3 5mm maximum from the safety switch surface The open close status of the contacts are maintained within the range When a gap is caused because of actuator relocation make sure that the gap does not lead to new risks 1 0mm 6 1 0mm 5 Entry Direction 1 9mm 7 W...

Страница 3: ...distorted during operation Make sure that no foreign objects are caught between the safety switch and mounting surface Uneven surface distorted surface or foreign objects may result in the malfunction of safety switch For Manual Unlocking Spring lock type The HS6E allows manual unlocking of the actuator to precheck proper door operation before wiring or turning power on as well as for emergency us...

Страница 4: ...sed Closed Closed Closed Closed Closed Closed Wiring Cable specifications UL style 2464 12c No 22AWG 80 C 300V Wire identification Wires are identified by the color and white line printed on the wire Do not use wire which is Gray Gray White Terminal number identification When wiring the terminal number on each contact is identified by wire color The following table shows the identification of term...

Страница 5: ... he machine equipment manufacturer to have applied the fault exclusion based on ISO13849 1 ISO13849 2 or IEC62061 Output Circuit Output Circuit S1 HS6E P4 Safety Switch with Solenoid S2 Starting Switch HW Series Momentary S3 Unlocking Enabling Switch S4 Safety limit Switch ESC Outside start condition K3 4 Safety Contactor F1 Outside fuse of safety relay module at power supply line Note Use the mon...

Страница 6: ...e insertion direction of the joint white plastic part See the figures below Do not lose the joints Actuators do not operate normally without a joint Horizontal Adjustment Vertical Adjustment Factory defalut Joint Accessories dimensions supplied Φ10 6 5 24 24 5 18 3 9 15 22 6 1 14 0 8 6 2 42 to 42 5 20 5 41 8 28 5 30 LED 0 8 15 20 1 37 15 C 1 2 20 5 2 3 41 8 28 5 46 1 10 4 10 1 12 6 1 5 14 4 4 R 2 ...