B-1906-1(0)
INSTRUCTION SHEET - HS6E Series
Solenoid Type Safety Switch
( 4 / 6 )
2016.08
6
Wiring
CAUTION
*10 Do not attempt manual unlocking when the solenoid is energized.
*11 Do not energize the solenoid for a long time while the door is open or when the
door is unlocked manually.
Door States
Door Manual Unlock Key
Door Monitor Circuit 11-12
21-22
31-32
Door Monitor Circuit 33-34
Lock Monitor Circuit 41-42
51-52
Lock Monitor Circuit 53-54
Solenoid Power
A1-A2
Door is locked.
The machine can
be operated.
The machine can
not be operated.
Door is unlocked.
The machine can
not be operated.
Door is unlocked.
The machine can
not be operated.
On
Open
Open
Closed
-
Closed
Closed
Off
Closed
Open
Closed
-
Closed
Open
Off/On *11
Closed
Closed
Open
-
Open
Open
Off *10,11
Closed
Open
Closed
Closed
Open
・
Solenoid Lock Type (HS6E-V
□
7Y)
Operation Cycle
• Spring Lock Type (HS6E-
□
4
)
・
Solenoid Lock Type (HS6E-
□
7Y
)
Turn the key
to
unlock position.
Turn the key
to
unlock position.
Door States
Door Manual Unlock Key
Main Circuit
11-42
Door Monitor Circuit 21-22
31-32
Door Monitor Circuit 33-34
Lock Monitor Circuit 51-52
Lock Monitor Circuit 53-54
Solenoid Power
A1-A2
On
Open
Closed
Open
Closed
-
Closed
Door is locked.
The machine can
be operated.
Closed
Off/On *11
Closed
Open
Closed
Open
-
Open
The machine can
not be operated.
Open
Off *10, *11
Closed
Open
Open
Open
Closed
Door is unlocked.
The machine can
not be operated.
Closed
Off
Closed
Open
Open
Open
-
Closed
Door is unlocked.
The machine can
not be operated.
Closed
Door States
Door Manual Unlock Key
Main Circuit
11-42
Door Monitor Circuit 21-22
31-32
Door Monitor Circuit 33-34
Lock Monitor Circuit 51-52
Lock Monitor Circuit 53-54
Solenoid Power
A1-A2
Off
Open
Closed
Open
-
Closed
On
Open
Open
Open
-
Closed
Off/On
Open
Open
-
Open
Off
Open
Open
Open
Turn the key
to
unlock position.
Closed
Door is locked.
The machine can
be operated.
The machine can
not be operated.
Door is unlocked.
The machine can
not be operated.
Door is unlocked.
The machine can
not be operated.
Closed
Open
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Wiring
• Cable specifications
UL style 2464, 12c×No.22AWG, (80°C 300V)
• Wire identification
Wires are identified by the color and white line printed on
the wire.
Do not use wire which is Gray, Gray / White.
Terminal number identification
• When wiring, the terminal number on each contact is identified by wire color. The
following table shows the identification of terminal numbers.
• When wiring, cut unnecessary wires such as unused wires to avoid incorrect wiring.
Insulator Color
Orange / White
Gray / White
White
Black
Insulator Color
Blue / White
Gray
Pink
Orange
No.
5
6
7
8
Insulator Color
Pink / White
Brown / White
Brown
Blue
No.
9
10
11
12
No.
1
2
3
4
Jacket
Colored Insulator
CAUTION
*9 The Actuator is inserted, and HS6E is locked.
• Contact operation is based on the condition that the actuator is inserted into the
center of the safety switch slot.
• Contact operation shows the HS9Z-A61, A62, A65, A66 actuators. (For HS9Z-A62S
actuator, decreases 0.6mm to contact operations)
• Terminals 12-41 are connected together internally. Use terminals 11-42 for safety
circuit inputs.
(without HS6E-V
□
)
• Indicator turns on when solenoid is energized.
Door States
Door Manual Unlock Key
Door Monitor Circuit 11-12
21-22
31-32
Door Monitor Circuit 33-34
Lock Monitor Circuit 41-42
51-52
Lock Monitor Circuit 53-54
Solenoid Power
A1-A2
Off
Open
Open
Closed
-
Closed
On
Closed
Open
Closed
-
Closed
Off/On
Closed
Closed
Open
-
Open
Off
Closed
Open
Closed
Turn the key
to unlock position.
Closed
Door is locked.
The machine can
be operated.
The machine can
not be operated.
Door is unlocked.
The machine can
not be operated.
Door is unlocked.
The machine can
not be operated.
Closed
Open
Open
Open
• Spring Lock Type (HS6E-V
□
4)
CAUTION
When using the outputs from the HS6E-V safety switch as inputs to safety circuits,
connect the door monitor circuits (11-12, 21-22, 31-32) and lock monitor circuits
(41-42, 51-52) in series. (GS-ET-19)
Then, the contact rating for he lock monitor circuit is applied.(HS6E-V
□
)
Circuit No.
11
12 / 42 (without HS6E-V
□
)
21
22
31, 33
32, 34
41 (HS6E-V
□
)
42 (HS6E-V
□
)
51, 53
52, 54
A1(-)
A2(+)
Insulator Color
Blue
Blue / White
Brown
Brown / White
Orange
Orange / White
Gray
Gray / White
Pink
Pink / White
Black
White
(without HS6E-V
□
)