Note : Confirm the outside diameter of the multi-core cable, the connector type 

depends on the outside diameter of multi-core cable.

Note : When using ST-M20×1.5, use with gasket GP-M (Type No: GPM20, made by 

LAPP).

Note : If you use HS1T as Type 4X 

Indoor Use Only

, please use M20 connectors that are 

certified the following.

 

Plastic connector: Type 4,4X, 6 or 6P 

 

Metal connector: Type 4X or 6P

Note : To unwire the terminals, disassemble the product in the following order: 
 

turn off the power → loosen connecter B → remove the terminal cover → 

remove the waterproof gasket from connecter A* → loosen connecter A

 

* Please remove the water-proof gasket carefully with tools such as tweezers. 

Be careful when removing the gasket as damages may affect its waterproof 

properties. Also, loosening connecter A without removing the gasket first may 

damage the cable and provoke connection issues. Please make sure you 

re-insert the waterproof gasket properly into connector A when re-assembling 

the product.

• Wiring Instructions
1. Insert the applicable screwdriver into 

the square-shaped port as shown,until 

the screwdriver tip touches the bottom 

of the spring.

3. While the screwdriver is retained in 

the port, insert the wire or ferrule into 

the round-shaped wire port. Each wire 

port can accommodate one wire or 

ferrule. 

Bottom of the Port

Safety Switch Terminal Cover

Gasket

Connecter

(To buy separately)

How to open conduit port (cable side-routed type)

• Before use, knock in the conduit port where the connector is to be connected, using 

a tool such as screwdriver as shown in the figures.

• Before opening the conduit port, remove the terminal cover from the HS1T Safety 

Switch main unit, and remove the locking ring for the cable gland installed in the 

terminal cover.

• Be sure to remove any crack or burrs on the conduit port, as it will impair waterproof 

performance.

Safety switch

Straight orientation

Horizontal orientation

Locking ring 

for cable gland

Terminal cover

A

B

4. Pull out the screwdriver. 

    The connection is now complete.

2. Push in the screwdriver until it touches 

    the bottom of the port. The wire port is 

    now open, and the screwdriver is held 

    in place. The screwdriver will not come 

    off even if you release your hand.

The waterproof 

gasket is completely

tightening the cable

The waterproof 

gasket is not 

properly tightening 

the cable 

Spring Force

Terminal

Spring Force

Terminal

Safety 

Switch

A

Gasket

Sheath

B

Terminal 

Cover

CAUTION

• Make sure not to lose any screw when 

removing the terminal cover from the 

switch.

• Please make sure the cable is insterted 

deep enough into the terminal cover so 

that the waterproof gasket can tighten 

he cable sheath completely and ensure 

its waterproof  functions.

• Make sure you always tighten connecter 

A before connecter B, otherwise the 

wires which connect the terminals might 

get twisted or might break, and this 

might also damage the terminal ports.

• When tightening the connecters, only 

use a tightening torque that is approved by the connecters' manufacturer to 

ensure waterproof properties of the product.

• Do not pull or twist the cable with excessive force, otherwise you might damage the 

wires inside of it.

Use a connector with a degree of protection IP67.
Applicable connector dimensions : See the figure on the right.
•  When using flexible conduit and metal connector
  Applicable Flexible Conduit Example:
   

Type VF-03 (made by Nihon Flex)

  (M20) Applicable Metal Connector Example:
   

Type RLC-103EC20 (made by Nihon Flex)

•  When using plastic connector, metal connector and multi-core cable
  (M20) Applicable Plastic Connector Example: 
   

Type ST-M20×1.5 (made by LAPP)

  Applicable Metal Connector Example: 
   

Type ALS-

□□

EC20 (made by Nihon Flex)

9mm max.

Conduit Thread

30mm max.

Applicable Connectors

A

B

Connecter (To buy separately)

Gasket

1. Loosen connecter A and connecter B, and insert the cable into these pieces in the 

following order : 

  connecter B  → waterproof gasket  → connecter A.
  Do not tighten the connecters yet.
2. Remove the terminal cover from the switch 

and insert the cable into the cover.

3. Wire the terminals.
4. Tighten connecter A into the terminal cover. 

Fix the terminal cover back into its original 

position. Tighten connector B.

Connecters' mounting method

Correct

The wire is inserted 

deep enough 

between the clamps

Incorrect

The wire insula ion 

sheath is in contact 

with the clamps

CAUTION

• When using wire with insulation 

diameter of Φ2.0mm or less, do not 

insert the wire too deep where the 

insulation inserts into the spring clamp 

opening. Otherwise conductive failure 

will be caused. Make sure that the 

wire insulation is stripped 8 to 9 mm 

and the wire is inserted to the bottom.

• Please only connect one wire per 

terminal port (according to the general 

requirements section (13.1.1) of 

IEC60204).

Содержание HS1T Series

Страница 1: ...cle 10 mA LED Green Type 2 Interlocking device low level coded actuator EN ISO ISO14119 EN ISO ISO14119 IEC60947 5 1 EN60947 5 1 GS ET 19 UL508 CSA C22 2 No 14 GB T 14048 5 IEC60204 1 EN60204 1 Low Voltage Directive Machinery Directive 2 5A AC Resistive load AC12 Inductive load AC15 DC Resistive load DC12 Inductive load DC13 30V 125V 250V 2 5A 1 5A 1 5A 0 75A 2 0A 0 4A 0 2A 1 0A 0 22A 0 1A Class I...

Страница 2: ...ctual applica ion before installation Actuator Mounting Reference Position As shown below the mounting reference position of the actuator inserted into the safety switch is After mounting the actuator remove the actuator stop from the safety switch When using the safety switch for a hinged door the minimum radius of the applicable door is shown in the following figures Minimum Radius of Hinged Doo...

Страница 3: ... cycling testing of the device to the control system to prevent product failure Regardless of door types do not use the safety switch as a door stop Install a mechanical door stop to the end of the door to protect the safety switch against excessive force Mount the actuator so that it will not hit the operator when the door is open other wise injury may be caused Pay attention to the management of...

Страница 4: ... safety hedge Use the rear unlock indicator by attaching it to the display area on either side of the safety switch The Rear Unlock Button Lock Release Rear Unlock Status Normal Status Contact Configuration and Operation Contact Congifiguration 11 9 HS1T TJ HS1T TG HS1T TF HS1T TD HS1T TC HS1T TB HS1T TA HS1T J HS1T G HS1T F HS1T D HS1T C HS1T B HS1T A HS1T XB HS1T DD HS1T VG HS1T VH HS1T VF HS1T ...

Страница 5: ...ng for guard locking devices Section 5 7 2 2 When a lock monitor circuit contact has the locking monitoring marking it means that one circuit contact can monitor the position and the locking function of the protective door The locking monitoring circuit contact turns ON only when the protective door is closed and locked note Both types of HS1T safety switches spring lock type switches and solenoid...

Страница 6: ...of gasket is completely tightening the cable The waterproof gasket is not properly tightening the cable Spring Force Terminal Spring Force Terminal Safety Switch A Gasket Sheath B Terminal Cover CAUTION Make sure not to lose any screw when removing the terminal cover from the switch Please make sure the cable is insterted deep enough into the terminal cover so that the waterproof gasket can tighte...

Страница 7: ...d by IDEC CORPORATION HS9Z A11T Actuator HS1T VB4 Safety Switch with Solenoid Used as open close monitor of guard Guard Open Output Circuit HR1S AF Safety relay module One of the example of the circuit Safety relay module HR1S AF series manufactured by IDEC CORPORATION HS9Z A11T Actuator HS1T VB4 Safety Switch with Solenoid Used as open close monitor of guard Guard Open Example of a circuit diagra...

Страница 8: ...ator Rear Unlock Button Rear Unlock Button RP RP 7 8 30 125 5 Main body moun ing hole layout HS9Z A12T Actuator HS9Z A11T Actuator Slot Plug 取付基準 Actuator center position 30 40 143 97 8 40 1 56 2 59 4 9 20 8 30 40 20 6 5 61 6 2 5 17 8 35 56 8 4 7 1 22 54 9 52 3 19 1 0 5 11 5 16 6 0 5 7 1 5 1 0 5 2 6 0 5 8 4 6 4 φ 5 2 φ 5 1 φ 5 1 7 8 30 97 8 HS9Z A11T Actuator HS9Z A12T Actuator HS9Z A11T Actuator ...

Страница 9: ... its validity Applicable EU Directive Low Voltage Directive 2014 35 EU Machinery Directive 2006 42 EC RoHS Directive 2011 65 EU Applicable Standard s EN 60947 5 1 GS ET 19 EN 50581 20 5 11 5 22 40 40 42 5 12 3 0 8 43 18 6 3 5 1 φ 5 1 φ 15 90 22 40 22 43 18 6 47 9 19 3 0 8 φ 5 1 φ 15 When installed on 3 5 1 Actuator Stop Supplied with actuator When installed on Actuator dimensions Type HS9Z A11T To...

Отзывы: