B-1908-1(0)
INSTRUCTION SHEET - HS1L Series
Solenoid Type Safety Switch, Inside Connector type
( 5 / 6 )
2016.08
7
Example of wiring Diagram realizing Safety Category
Example of a circuit diagram for Safety Category 4
(attainable PL = e)
Example of a circuit diagram for Safety Category 3
(attainable PL = d)
(Condition 1: To apply the fault exclusion of mechanical structural parts including the actuator
→ Make sure to use the product within he product specification range described in his
manual and the version of the manual provided wi h the product.)
(Condition 2: Documentation of the reason for the machine/equipment manufacturer to have
applied the fault exclusion based on ISO13849-1, ISO13849-2 or IEC62061.)
Guard Open
DC24V
S3
F1
K4
K3
HS1L-DQ4
Safety Switch with Solenoid
HS9Z-A1S Actuator
DC0V
A1(-)
A2(+)
52
S1
12
11
HR1S-AF Safety relay module
13
14
ESC
K4
K3
S2
51
42
41
22
21
S33
S34
13
23
A1
S11
S22
14
24
A2
S12S21
34
33
64
63
L1(+)
N(−)
One of the example of
the circuit ; Safety
relay module, HR1S-AF
series manufactured
by IDEC CORPORATION
Used as
open / close
monitor of guard
Used as
lock / unlock
monitor
Output Circuit
S1: HS1L-DQ4 Safety Switch with Solenoid
S2: Starting Switch (HW Series Momentary)
S3: Unlocking Enabling Switch
S4: Safety limit Switch
ESC: Outside start condition
K3, 4: Safety Contactor
F1: Outside fuse of safety relay module at power supply line
Guard Open
HS1L-DQ4
Safety Switch with Solenoid
HS9Z-A1S Actuator
DC24V
S3
F1
K4
K3
DC0V
A1(-)
A2(+)
52
S1
12
11
HR1S-AF Safety relay module
13
14
ESC
K4
K3
S2
51
42
41
22
21
S33
S34
13
23
A1
S11
S22
14
24
A2
S12S21
34
33
64
63
S4
1
2
L1(+)
N(−)
One of the example of
the circuit ; Safety
relay module, HR1S-AF
series manufactured
by DEC CORPORATION
Used as
open / close
monitor of guard
Used as
lock / unlock
monitor
Output Circuit
Note: Use the monitoring device(Safety relay module) provided the capavility to
detect a cross short circuit. The insulation of the cable has to withstand
environmental influences. If a control device other than the one shown in the
draft is used, the used control device has to be equipped with a cross short
circuit monitor.