Programming IDEC SmartRelay
92
IDEC SmartRelay Manual
3.6.8
Deleting a block
Let us assume you want to delete the block B2 from your
circuit program and connect B1 directly to Q1.
Q1
I1
I2
x
x
Par
B1
B2
Proceed as follows:
1. Switch IDEC SmartRelay to programming mode
(as a reminder, refer to Page 66).
2. Select ’
Edit
’:
Press or
3. Confirm ’Edit’:
Press
OK
(If required, enter your password and confirm with
OK
.)
4. Select ’
Edit Prg
’:
Press or
5. Confirm ’Edit Prg’:
Press
OK
6. Move the cursor to B2, the input of Q1
Press :
B2
Q1
7. Confirm with
OK
.
8. Now replace block B2 with block B1 at output Q1. The
procedure:
-
Select the
BN
list:
Press or
-
Accept the BN list:
Press
OK
-
Select ’
B1
’:
Press or
-
Apply ’B1’:
Press
OK
Result:
Block B2 is deleted, because it is no longer used in
the circuit. Block B1 has replaced B2 directly at the output.