47
Installing the Standard Control Panel
48
Standard Control Panel
•
Position the control panel on the rear studs
①
.
•
Open the control panel (3 screws at the back)
②
.
•
Bring the burner cable behind the casing support and down
to the burner between the side panel and insulating material.
49
Standard Control Panel
•
Fasten the control panel to the panel base with two ø 3.94
x 25 tapping screws and serrated washers
①
.
•
Carefully unroll the various bulbs and bring them out of the
control panel through the opening designed for that
purpose. Cut out the top insulating material and insert the
bulbs in the boiler pocket and hold them in place using the
spring
②
.
•
Fasten
rear cover H
(package
FA5 or FA6
) to the control
panel bracket using two EC CB 4 x 40 screws and serrated
washers
③
.
•
Make the
electrical connections
to the two terminal blocks
provided for this purpose inside of the control panel. See
the “Electrical Connections” section of the instructions
(Section 7, page 41).
•
Close the control panel.
3 x
1
2
2
VIS5118
REAR
FRONT
VIS5119
VIS5120