Fault

Potential Corrective Actions

Central Heating will not 

switch off

Check that the timer tappets are set to the inner edge of the dial.

Check the room temperature is not below 5ºC (frost protection).
Rotate the room thermostat knob until the set point is 5ºC
Check that the Timer On/Timed/Off switch is off ( or the unit is timed off)
Stand next to the boiler holding the room thermostat for 5 mins.  If the 

central heating switches off then the room thermostat was either too far 

away from the boiler or there were unsuitable materials between the 

boiler and the room thermostat.  Re-position room thermostat.
Change the batteries in the room thermostat.
Replace both the RF Timer and the RF Room Thermostat for a new pair.

Fault Help

Содержание RF Electronic

Страница 1: ...SER GUIDE When replacing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal ...

Страница 2: ...be observed Interferences and changes to the device will lead to cancellation of the warranty RF Electro Mechanical Timer 4 RF Room Thermostat 5 Room Temperature 6 Setting the time 7 Timed On Off 8 Setting the Central Heating On Off Times 9 Fault Help 10 11 Battery Replacement 12 ...

Страница 3: ...c Combi ES Logic Code Combi Logic Code Combi ES RF Electro Mechanical Timer RF Room Thermostat Continuously OFF Continuously ON Room Stat Signal ON off on Timed DO NOT Turn Anti Clockwise 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 14 1 5 1 6 1 7 1 8 1 9 20 2 1 2 2 23 24 1 RFT1 RT1 Set ºC 23 5 ...

Страница 4: ...1 5 1 6 1 7 1 8 1 9 20 2 1 2 2 23 24 1 RFT1 off on Program Tappets Heat Demand RF Signal Strength Indication On Timed Off Switch Actual Time Note The heat demand indicator will be illuminated whenever both the timer and room thermostat indicate that central heating is required Note RF signal strength light illuminates green for good signal and red for a poor signal ...

Страница 5: ...play Set Temperature shown when knob rotated Temperature Setting Knob Low Battery Indication Note If the low battery symbol is visible or the display is blank then replace the batteries Frost Protection Operation will occur if the Room Temperature is less than 5ºC Set ºC 23 5 Room Thermostat ...

Страница 6: ...6 RT1 Temperature Setting Knob To set the Room Temperature rotate the knob until the desired temperature is shown on the display Set ºC 23 5 Room Temperature ...

Страница 7: ... current time Rotate the dial slowly in a clockwise direction until the correct hour is aligned with the arrow printed on the dial Note that the outer dial is printed with 24 hour clock 8 00 am 8 on the dial 8 00pm 20 on the dial Clock hands will allow for fine adjustment of the current time setting of the dial Do not attempt to rotate the dial in an anti clockwise direction 2 3 4 5 6 7 8 9 10 11 ...

Страница 8: ... Room Stat Signal ON Timed DO NOT Turn Anti Clockwise 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 14 1 5 1 6 1 7 1 8 1 9 20 2 1 2 2 2 3 24 1 RFT1 off on On Timed Off Switch To set the timer for Continuously On Timed or Continuously Off operation slide the On Timed Off switch into the desired position ...

Страница 9: ...N Room Stat Signal ON Timed DO NOT Turn Anti Clockwise 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 14 1 5 1 6 1 7 1 8 1 9 20 2 1 2 2 2 3 24 1 RFT1 Tappets set to OFF period Tappets set to ON period Set Tappets to outer edge for ON periods Set Tappets to inner edge for OFF periods off on ...

Страница 10: ...ns connection to the boiler is in place across the room stat connections see boiler installation instructions Check that the Timer On Timed Off switch is on or the unit is timed on Stand next to the boiler holding the room thermostat for 5 mins If the central heating switches on then the room thermostat was either too far away from the boiler or there were unsuitable materials between the boiler a...

Страница 11: ...eck that the Timer On Timed Off switch is off or the unit is timed off Stand next to the boiler holding the room thermostat for 5 mins If the central heating switches off then the room thermostat was either too far away from the boiler or there were unsuitable materials between the boiler and the room thermostat Re position room thermostat Change the batteries in the room thermostat Replace both t...

Страница 12: ...using a flat headed screwdriver inserted into the slot underneath the unit Note that if the batteries are removed for more than 30 seconds the set temperature will be lost If the batteries are not replaced and no signal is received by the receiver the red room stat signal light will be illuminated on the boiler mounted RF Timer After 1 hour the boiler will operate in Emergency Mode with a continuo...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...N Tel 01482 492251 Fax 01482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice April 2014 UIN 208937 A02 ...

Отзывы: