27
istor system store -
Installation and Servicing
INSTALLATION
FLUE OUTLET
WARNING.
Ensure that, during the cutting operation, masonry falling outside of the building does not cause damage or
personal injury.
1.
Cut the flue hole (preferably with a 5" core boring tool), ensuring that the hole is square to the wall.
Both wall faces immediately around the cut hole should be flat.
29 PREPARING THE WALL
ist9839
For pipe lengths greater than 5.5m, or any flue length to be outside of the wall, increase
the off-set by 26mm for every additional metre to maintain 1.5
o
- 3
o
inclination.
1
ist8792
28 FLUE ASSEMBLY - Exploded View
LEGEND
1.
Duct assembly.
2.
Flue Turret.
3.
Turret seal.
4.
M5 x 10 pozi screw.
5.
Turret clamp.
1.
An optional flue duct extension kit is required for flue lengths
greater than :
RH Side
595mm
LH Side
595mm
Rear
595mm
Rear flue arrangement shown
ist9838
For pipe lengths greater than 5.5m, or any flue length to be outside of the wall, increase
the off-set by 26mm for every additional metre to maintain 1.5
o
- 3
o
inclination.