Independent System - 

User’s

Condensate Drain

This appliance is fitted with a siphonic condensate trap 

system that reduces the risk of the appliance condensate 

from freezing.  However should the condensate pipe to this 

appliance freeze, please follow these instructions:
a.  If you do not feel competent to carry out the defrosting 

instructions below please call your local Gas Safe 

Registered installer for assistance.

b.  If you do feel competent to carry out the following instructions 

please do so with care when handling hot utensils.  Do not 

attempt to thaw pipework above ground level.

If this appliance develops a blockage in its condensate pipe, 

its condensate will build up to a point where it will make a 

gurgling noise prior to locking out an “L2” fault code.  If the 

appliance is reset it will make a gurgling noise prior to it 

locking out on a failed ignition “L2” code.
To unblock a frozen condensate pipe;
1.  Follow the routing of the plastic pipe from its exit point on 

the appliance, through its route to its termination point.

  Locate the frozen blockage.  It is likely that the pipe is 

frozen at the most exposed point external to the building 

or where there is some obstruction to flow.  This could be 

at the open end of the pipe, at a bend or elbow, or where 

there is a dip in the pipe in which condensate can collect.  

The location of the blockage should be identified as closely 

as possible before taking further action.

2.  Apply a hot water bottle, microwaveable heat pack or a 

warm damp cloth to the frozen blockage area.  Several 

applications may have to be made before it fully defrosts.  

Warm water can also be poured onto the pipe from a 

watering can or similar.  DO NOT use boiling water.

3.  Caution when using warm water as this may freeze and 

cause other localised hazards.

4.  Once the blockage is removed and the condensate can 

flow freely, reset the appliance. (Refer to “To Light the 

boiler”)

5.  If the appliance fails to ignite, call your Gas Safe 

Registered engineer.

preventative solutions

During cold weather, set the boiler stat to maximum, (Must 

return to original setting once cold spell is over)
Place the heating on continuous and turn the room stat down 

to 15ºC overnight or when unoccupied. (Return to normal after 

cold spell).

Escape of gas

Should a gas leak or fault be suspected contact the National Gas 

Emergency Service without delay. 

Telephone 0800 111 999

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth. 
To remove stubborn marks and stains, wipe with a damp cloth and 

finish off with a dry cloth. 

DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a Gas 

Safe Registered Engineer or in IE a Registered Gas Installer 

(RGII).

Содержание independent 15

Страница 1: ...rformance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification and maintenance p...

Страница 2: ...ed out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813 Domestic Gas Installations the current Building Regulations and reference should be made to th...

Страница 3: ...ided and frost is likely during a short absence from home leave the heating controls if fitted at a reduced temperature setting For longer periods the entire system should be drained If the system inc...

Страница 4: ...dip in the pipe in which condensate can collect The location of the blockage should be identified as closely as possible before taking further action 2 Apply a hot water bottle microwaveable heat pack...

Страница 5: ...the time settings on the programmer are as you require and adjust if necessary Check the programmer is in an ON position and the room thermostat is turned up NO See boiler Operation Modes and Fault C...

Страница 6: ...ting either a central heating call or hot water demand The boiler has a call for central heating hot water but the appliance has reached the desired temperature set on the boiler The boiler is operati...

Страница 7: ...he boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII F...

Страница 8: ...482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specifica...

Отзывы: