20
Operating instructions
6.2
ACCESS CODE SETTING
Setting for solar panel use
Use as solar panel sensor a PT 1000 sensor
Expert area
⇒
Solar/ MF
⇒
FUNC RELAY 4 “23”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
0 0 0 0
NUM CODICE
0 0 0 0
0 0 0 0
0 0 0 0
Depress the programming push
botton to set the access code
NOTE:
To modify or to
display some pa-
rametres is ne-
cessary to set
the access code
6.1
OTHER POSSIBLE SETTINGS
Settings for heating circuit 1 \ 2
Heating adjustement with constant flow temperature
(without outer sensor)
It offers the possibility to have a constant flow temperature on
the selected heating circuit.
⇒
HC FUNC “01”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
temperature Settings for heating circuits
(Only after function selection)
User Area
⇒
Heating circuit I / II
⇒
FLOW TEMP DAY
User Area
⇒
Heating circuit I / II
⇒
FLOW TEMP NIGHT
A second DHW storage tank
(Only after function selection)
It offers the possibility to use one of the heating zone for the
preparation of a second DHW storage tank
Expert area
⇒
Heating circuit I/II
⇒
HC FUNC. “03”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
Temperature setting for second DHW storage tank
User AREA
⇒
Heating circuit / II
⇒
T- HW
Swimming pool
It offers the possibility to use one of the heating zone for the
heating of a swimming pool
Wires the pool temperature sensor to connector (III 1+2)
Expert area
⇒
Heating circuit I/II
⇒
HC FUNC “02”
(
For additional informations refer to the E8 instruction
manual supplied with the boiler.
Swimming pool temperature setting
(Only after function selection)
User Area
⇒
Heating circuit I / II
⇒
T- POOL 1 / 2 / 3
Screed dry programm
(floor heating installation)
Setting of a program for drying the screed
Expert area
⇒
Installation
⇒
SCREED “01”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
Temperature setting for screed program
User Area
⇒
Heating circuit I / II
Signal 0 – 10 V
Inlet of 0-10 V signal for slope control trough en outer regulator
(connect F15)
Expert area
⇒
Solar/MF
⇒
FUNC. F15 “01”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
Slope and temperature setting with 0 – 10 V signal
Expert Area
⇒
Installation
⇒
TENS SLOPE (0 to 11)
Expert Area
⇒
Installation
⇒
SLOPE 11 – XX (freely
settable)
Setting of DHW circuit
Operation of pumps in parallel
Possibiliti to keep in operation the heating pumps also during
DHW production.
Expert area
⇒
Hot water
⇒
F-PUMP PARAL “00,01,02,03”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
Use of a DHW storage tank thermostat (on/off)
It is possible to use an ON - OFF thermostat instead of DHW
sensor
Expert area
⇒
Hot water
⇒
THER IMPUT “01”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
Antilegion
Activation of an antilegion program
Expert area
⇒
Hot water
⇒
ANTILEGION “01”
For additional informations refer to the E8 instruction manual
suppl
i
ed with the boiler.
U1 = Volt min
U2 = Volt max
T1 = T min (volt min)
T2 = T max (volt max)
UA = Off
(U = tension;
T = temperature;
1 = Min;
2 = Max;
UA = Off; )