Esprit eco

 - 

Installation and Servicing

Condensate Drain

This appliance is fitted with a siphonic condensate trap system 

that reduces the risk of the appliance condensate from freezing.  

However should the condensate pipe to this appliance freeze, 

please follow these instructions:

a.  If you do not feel competent to carry out the defrosting 

instructions below please call your local Gas Safe Registered 

installer for assistance.

b. 

If you do feel competent to carry out the following instructions 

please do so with care when handling hot utensils.  Do not attempt 

to thaw pipework above ground level.

If this appliance develops a blockage in its condensate pipe, its 

condensate will build up to a point where it will make a gurgling 

noise prior to locking out an “L2” fault code.  If the appliance is 

reset it will make a gurgling noise prior to it locking out on a failed 

ignition “L2” code.

To unblock a frozen condensate pipe;

1.  Follow the routing of the plastic pipe from its exit point on the 

appliance, through its route to its termination point.

  Locate the frozen blockage.  It is likely that the pipe is frozen 

at the most exposed point external to the building or where 

there is some obstruction to flow.  This could be at the open 

end of the pipe, at a bend or elbow, or where there is a dip in 

the pipe in which condensate can collect.  The location of the 

blockage should be identified as closely as possible before 

taking further action.

2.  Apply a hot water bottle, microwaveable heat pack or a warm 

damp cloth to the frozen blockage area.  Several applications 

may have to be made before it fully defrosts.  Warm water 

can also be poured onto the pipe from a watering can or 

similar.  DO NOT use boiling water.

3.  Caution when using warm water as this may freeze and 

cause other localised hazards.

4.  Once the blockage is removed and the condensate can flow 

freely, reset the appliance. (Refer to “To Light the boiler”)

5.  If the appliance fails to ignite, call your Gas Safe Registered 

engineer.

Preventative solutions
During cold weather, set the boiler stat to maximum, (Must return 

to original setting once cold spell is over)
Place the heating on continuous and turn the room stat down to 

15ºC overnight or when unoccupied. (Return to normal after cold 

spell).

Escape of gas

Should a gas leak or fault be suspected contact the National Gas 

Emergency Service without delay. 

Telephone 0800 111 999

Do nOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth. 

To remove stubborn marks and stains, wipe with a damp cloth 

and finish off with a dry cloth. 

dO nOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a Gas 

Safe Registered Engineer or in IE a Registered Gas Installer 

(RGII).

Loss of system water pressure

The gauge (H) indicates the central heating system pressure. 

If the pressure is seen to fall below the original installation 

pressure of 1-2 bar over a period of time then a water leak may 

be indicated. In this event re-pressurise the boiler.  If unable to 

do so or if the pressure continues to drop a Gas Safe Registered 

Engineer or in IE a Registered Gas Installer (RGII) should be 

consulted.  

InDICATED By “F1” (LOW WATER PRESSURE) - THE BOILER 

WILL nOT OPERATE IF THE PRESSURE HAS REDUCED TO 

LESS THAn 0.3 BAR UnDER THIS COnDITIOn.

3

3G9933

PRESSURE GAUGE

Содержание Esprit eco 30

Страница 1: ...reverse of book When replacing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or c...

Страница 2: ...gistered Engineer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813...

Страница 3: ...the system then the CH Temperature Control C becomes a method of controlling room temperature Turn the knob clockwise to increase room temperature and anti clockwise to decrease room temperature Once...

Страница 4: ...o be made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause othe...

Страница 5: ...Note The segment dial can be turned when the time controller is operating In case of power failure re adjust the time controller to the correct time of day turning the dial in a clockwise direction Pe...

Страница 6: ...boiler operate and provide central heating Check the time settings on the programmer are as you require and adjust if necessary Check the timer is in an ON position and the room thermostat is turned u...

Страница 7: ...call for central heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the b...

Страница 8: ...LER DESCRIPTION Low Water Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal Boilers if under warranty or alternat...

Отзывы: