background image

7

Concord CXDi/H - 

Users

1.

Always follow these instructions.

2.

Correct ventilation is essential for safe operation of
the boiler. Do NOT obstruct ventilation ducts, grilles or
openings in the boiler room, or the passage of
combustion and ventilation air to the boiler.

3.

Do NOT store objects around or on the boiler, and
keep access clear at all times.

4.

Switch OFF and disconnect the electricity before
carrying out maintenance work.

Remember !

 

The ON/STANDBY [1/0] button  does

NOT

 electrically isolate the boiler.

5.

Do NOT turn off the boiler if it is to be left unattended
in frosty weather.

9 USING THE BOILER FEATURES AND CONTROLS - continued

Delayed High Rate Gas valve Operation

When the boiler is started from cold the high rate gas valve
will be delayed for 3 minutes and then energised. If the boiler
flow temperature is equal to or greater than 55 

o

C then this

delay will NOT occur.

Notes.

1.

If a fault occurs with the boiler thermostat the fault
display screen will show "C/H Sensor Fault".

2.

When the low rate gas valve is de-energised, as the
temperature required has been obtained, the boiler will
go into an anti-cycle route for 2 minutes. The display
will indicate anti-cycle and the current flow
temperature.

SERVICING

This is for use by the installer / service engineer only.

COMMISSIONING

This is for use by the installer / service engineer only.

OUTSIDE SENSOR  (if fitted)

Information will be provided with the kit.

10 GENERAL CARE

WARNING

.  

This appliance 

MUST

 be efficiently earthed.

CLEANING

F

or normal cleaning simply dust with a dry

cloth.

To remove stubborn marks and stains use a
damp cloth and mild detergent.

Do NOT use abrasive cleaning materials.

MAINTENANCE

The boiler should be serviced at least once a
year by a CORGI registered installer.

Содержание Concord CXDi 110

Страница 1: ...USERS G U I D E User s guide to commercial central heating boilers BOILERS Concord CXDi 110 H 180 H ...

Страница 2: ...SENSOR Optional extra If the optional outside sensor is fitted the control system will recognise this and automatically regulate the boiler flow temperature to changes in the external temperature If the sensor is fitted an extra status information screen will appear stating whether the device has been activated or not i e Sensor on off COMMISSIONING INSTRUCTIONS These are provided to assist the in...

Страница 3: ...mises the risk of this but in addition the controls prevent the boiler from short cycling by preventing subsequent ignition within a period of 2 minutes When active the display will show ANTI CYCLE Flow temp 4 TO LIGHT THE BOILER CONTROLS 5 TO SHUT DOWN THE BOILER the groove in the square head must be at right angles to the line of the pipe and refit the casing panel Note If severe weather frost c...

Страница 4: ...4 Concord CXDi H Users 6 USING THE BOILER FEATURES AND CONTROLS The diagram below shows the sequence of steps to be taken when reading the instructions on the following pages ...

Страница 5: ... button will access the above options in reverse When the option required is displayed and the ENTER button pressed another set of menus will be available as discussed on the following pages PROGRAMMER TIMER The programmer has 3 time zones per day for each day of the week Each day can be programmed for the requirements of that day giving 7 programmed days or using the copy facility any number of d...

Страница 6: ... it cycles between high and low operation the boiler will fall through 30 before the high rate gas valve is energised 8 USING THE BOILER FEATURES AND CONTROLS continued SET TIME DATE Enables the correct time and date to be entered The display will show a flashing day of the week as follows The correct day can be selected by use of the UP or Down button and when correct the ENTER button should be p...

Страница 7: ...en energised If the boiler flow temperature is equal to or greater than 55 o C then this delay will NOT occur Notes 1 If a fault occurs with the boiler thermostat the fault display screen will show C H Sensor Fault 2 When the low rate gas valve is de energised as the temperature required has been obtained the boiler will go into an anti cycle route for 2 minutes The display will indicate anti cycl...

Страница 8: ...P O Box 103 National Ave Kingston upon Hull HU5 4JN Telephone 01482 492 251 Fax 01482 448 858 Registration No London 322 137 Caradon Ideal Limited pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice ...

Отзывы: