600 AAC Clamp Meter

Instruction Manual

NCV

OFF

V

Ω

V

True RMS

40

A

600

A

M

HOLD

DC

K

AC

m

Ω

V

APO

CAT.III

600V

600A

CLAMP

61-746

CAT.III

600V

V

/

Ω

 

COM

WARNING

Read First:  Safety Information

Understand and follow operating instructions carefully.  Use the meter only as
specified in this manual; otherwise, the protection provided by the meter may be
impaired.

WARNING

To avoid possible electric shock, personal injury or death, follow these
guidelines:

• Do not use if meter appears damaged.  Visually inspect the meter to ensure

case is not cracked and back case is securely in place.

• Inspect and replace leads if insulation is damaged, metal is exposed, or probes

are cracked.  Pay particular attention to the insulation surrounding the
connectors.

• Do not use meter if it operates abnormally as protection maybe impaired.  
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, or vapor.
• Do not apply more than the rated voltage to the meter. 
• Do not use without the battery and the back case properly installed.
• Remove the test leads from the circuit prior to removing battery cap.
• Do not attempt to repair this unit as it has no user-serviceable parts.
• Replace batteries as soon as low battery indicator         appears to avoid false

readings.

• Comply with local and national safety requirements, including the use of

appropriate personal protective equipment.

+

 

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

 

Visit us at www.T

estEquipmentDepot.com

Back to the 

Ideal 61-746

 Product Info Page

Содержание 61-744

Страница 1: ...e cracked Pay particular attention to the insulation surrounding the connectors Do not use meter if it operates abnormally as protection maybe impaired Do not use during electrical storms or in wet weather Do not use around explosive gas dust or vapor Do not apply more than the rated voltage to the meter Do not use without the battery and the back case properly installed Remove the test leads from...

Страница 2: ...ective equipment such as safety glasses face shields insulating gloves insulating boots and or insulating mats Before each use Perform a continuity test by touching the test leads together to verify the functionality of the battery and test leads Use the 3 Point Safety Method 1 Verify meter operation by measuring a known voltage 2 Apply meter to circuit under test 3 Return to the known live voltag...

Страница 3: ...hen powered on In this mode the meter automatically selects the best range to display the measurement By pressing the Range button on the meter the manual range mode will override the auto ranging feature of the meter A appears in the upper left side of the display Continue pressing the Range button until the desired range is obtained Use this mode to lock in a specific range for repeated measurem...

Страница 4: ...est leads from input jacks on meter Remove the two screws from the battery cap Remove the battery cap Replace batteries with two AAA batteries Assemble the battery cap to the meter and re tighten the screws Maintenance Clean the case with a damp cloth and mild detergent Do not use abrasives or solvents Service and Replacement Parts This unit has no user serviceable parts For replacement parts or t...

Страница 5: ...mplied negative polarity indication Overrange OL indication is displayed Measure Rate Samples 2 times per second nominal Auto Power Off Approximately after 10 minutes of non use Battery Life 400 hours continuous with Alkaline 61 744 250 hours continuous with Alkaline 61 746 Low Battery Indication The is displayed when battery voltage drops below operating level Power Supply 2 1 5V AAA batteries NE...

Отзывы: