background image

v

A1009091 - 661A0600_EN • A

v

SAFE

TY

PRODUCT AND SAFETY INFORMATION

This manual contains important information for the installation, 
starting up and maintenance of the appliance.
This manual must be provided to the Homeowner, who will  
keep it in a safe place for future reference.

Ideal North America accepts no liability for any 

damage, injury, or loss of life resulting from incorrect 

installation,  alteration of any factory supplied 

parts, or the use of parts or fittings not specified 

by Ideal. If there is a conflict or doubt about the 

proper installation of the unit or any factory supplied  

replacement parts please contact Ideal Technical 

Support.

DEFINITIONS

The following terms are used throughout this manual 

to bring attention to the presence of potential hazards 

or to important information concerning the product.

Indicates the presence of a hazardous situa-

tion which, if ignored, will result in substantial 

property damage, serious injury, or death.

Indicates a potentially hazardous situation 

which, if ignored, can result in substantial 

property damage, serious injury, or death.

Indicates a potentially hazardous situation 

which, if ignored, can result in minor property 

damage, or injury.

Indicates special instructions on installation, 

operation or maintenance, which are import-

ant to the equipment but not related to person-

al injury hazards.

Indicates recommendations made by Ideal for the 

installers, which will help to ensure optimum op-

eration and longevity of the equipment.

 

DANGER

 

WARNING

CAUTION

NOTICE

BEST PRACTICE

BEST PRACTICE

IMPORTANT SAFETY INFORMATION FOR 
THE HOMEOWNER AND THE INSTALLER

 

DANGER

•  Water  temperatures  over  125ºF  can  cause severe 

burns instantly or death from scalding.

Hot Water Can Scald!

•  Children, disabled and elderly are at highest risk of 

being scalded.

•  Never leave them unattended in or near shower, 

bathtub or sink.

•  Never allow small children to use a hot water faucet 

or draw their own bath.

•  If anyone using hot water in the building fits the 

above description or if local codes or state laws 

require specific water temperatures at hot water 

faucet, it is recommended:

-  To install a thermostatic mixing valve at this 

appliance or at each water faucet.

or
-  To set the thermostat knob for the lowest 

temperature which satisfies your hot water needs.

•  Water drained from the system drain valves may be 

extremely hot.  To avoid injury:

–   Make sure all connections are tight.
–   Direct water flow away from any person.

Bacteria can develop in the domestic water 

system if certain minimum water tempera-

tures are not maintained. Failure to maintain 

at least 140°F [60°C] domestic hot water tem-

perature (using the Antilegionella function 

of your boiler, if any) can result in bacteria 

development, which can result in serious in-

jury, or death.

 

WARNING

Water Temp.

Time for 3rd degree  

burn to occur

104 ° F 

Safe for bathing

120 ° F 

5 minutes 

125 ° F 

2 minutes

130 ° F 

10 seconds

140 ° F 

3 seconds

148 ° F 

2 seconds 

155 ° F

1 second

Содержание MONARCH 30

Страница 1: ...ld be performed by a licensed plumber or gas fitter in the Common wealth of Massachusetts NOTICE This document is intended to be used by a factory trained and qualified heating contractor or service t...

Страница 2: ...5 2 1 2 Commonwealth of Massachusetts Installation 5 2 1 3 T P Relief Valve Discharge Piping 5 2 2 Drain Valve 6 2 2 1 Standard Installation 6 2 3 Thermal Expansion 6 2 4 Water Hammer 6 2 5 Vacuum Br...

Страница 3: ...technician should include the following 18 5 1 2 Homeowner monthly maintenance to include 18 5 2 Filling Water Heater 18 5 3 Draining Water Heater 18 5 3 1 Preparation for Draining the Tank 19 5 3 2...

Страница 4: ...Domestic Priority 12 Fig 9 MONARCH System Piping with Zone Circulators 12 Fig 10 Multiple MONARCH Series Water Heater System Boiler Piping Reverse Return Balanced Flow 13 Fig 11 Multiple MONARCH Seri...

Страница 5: ...hazards IndicatesrecommendationsmadebyIdealforthe installers which will help to ensure optimum op erationandlongevityoftheequipment DANGER WARNING CAUTION NOTICE BEST PRACTICE BEST PRACTICE IMPORTANT...

Страница 6: ...the appliance is required Failure to comply with these instructions can result in minor property damage or injury In case of any concern please call your qualified service technician Make sure to refe...

Страница 7: ...RCH wa ter heater complies with National Standard Plumbing Code provided that Boiler water including additives is practically non toxic having toxicity rating or class of 1 as listed in Clinical Toxic...

Страница 8: ...30 psig Water quality limitations based on E P A National Secondary Drinking Water Regulations See Table 2 on page 3 In hard water areas more than 7 grains of hardness use a water softener on the cold...

Страница 9: ...ential failure of the product and will void the warranty CAUTION During installation and during the annual maintenance the water quality must be checked and if found outside of the requirements must b...

Страница 10: ...n either the heating and or domestic circuits must be taken into account Recommended top or vertical clearance is 12 minimum Refertoboilermanualforboilerclearances Fig 1 MONARCH Clearances View from t...

Страница 11: ...sachusetts and in all jurisdictions requiring a vacuum breaker to be installed on the domestic cold water inlet follow these requirements The water heater shall be protected against loss of water from...

Страница 12: ...a lent on the domestic cold water inlet will prevent dam age to the tank if a negative pressure is developed in the domestic supply line See manufacturer s instructions for application and installatio...

Страница 13: ...Install automatic mixing valve either at the hot wa ter outlet of water heater or each hot water faucet DANGER Table 4 Piping dimensions Water Heater Model Connections inches Minimum Boiler Piping Do...

Страница 14: ...nk and void the warranty Boiler water including additives must be practical ly non toxic having toxicity rating or class of 1 as listed in Clinical Toxicology of Commercial Prod ucts 5th Edition If an...

Страница 15: ...n tank potable 9 Recirculation connection 10 Thermostatic mixing valve Recommended devices may be required by local codes Cold Water Inlet 6 1 12 min Heat Trap Loop Optional 12 min Heat Trap Loop Opti...

Страница 16: ...mixing valve at either the hot water outlet of the water heater system or at each hot water fixture Each tank should be equipped with a drain valve see Fig 2 on page 9 Recommended for applications in...

Страница 17: ...1 6 5 Cold water inlet 4 Fig 6 MONARCH System Piping with 3 Port Zone Valve Domestic Priority Fig 7 MONARCH System Piping with 2 Port Zone Valves Domestic Priority 11 A1009091 661A0600_EN A 11 CHAPTER...

Страница 18: ...ld water inlet 1 2 2 2 7 7 7 4 Fig 8 MONARCH System Piping with Zone Valves Non Domestic Priority Fig 9 MONARCH System Piping with Zone Circulators 12 A1009091 661A0600_EN A 12 CHAPTER 2 CHAPTER 2 INS...

Страница 19: ...ter System Boiler Piping Reverse Return Balanced Flow Fig 11 Multiple MONARCH Series Water Heater System Boiler Piping Manifold 13 A1009091 661A0600_EN A 13 CHAPTER 2 CHAPTER 2 INSTALLATION PIPING 1 S...

Страница 20: ...Gallant Boiler Low Voltage Terminal 14 A1009091 661A0600_EN A 14 Chapter 3 INSTALLATION WIRING 3 1 Temperature Sensor and Drywell Gallant and Exalt boilers are equipped with a sensor that can be used...

Страница 21: ...A1009091 661A0600_EN A 15 CHAPTER 3 CHAPTER 3 INSTALLATION WIRING Consumer Product Safety Commission and some states recommend temperatures set tings of 120 F or less Setting thermostat high er than 1...

Страница 22: ...by allowing water to run until there is a constant flow of water 4 Close hot water faucet CAUTION WARNING CAUTION HOT WATER CAN SCALD Water temperature over 125 F can cause se vere burns instantly or...

Страница 23: ...develop in the domestic water system if certain minimum water tempera tures are not maintained Failure to maintain at least 140 F 60 C domestic hot water tem perature using the Antilegionella functio...

Страница 24: ...ities and their frequencies including any not listed in the following section WARNING DANGER 5 1 2 Homeowner monthly maintenance to in clude Check for air Manual air vent open and close briefly to re...

Страница 25: ...a plumbing fix ture in the building until cool water is coming out of the hot water faucet Opening multiple hot water faucets will speed up the process 2 Close the DHW cold water valve and allow water...

Страница 26: ...1 2 20 A1009091 661A0600_EN A 20 CHAPTER 5 Chapter 6 REPLACEMENT PARTS Fig 14 MONARCH Assembly...

Страница 27: ...Tube 40 CTRKIT302 MONARCH 50 Dip Tube 50 CTRKIT303 MONARCH 60 Dip Tube 60 CTRKIT304 MONARCH 80 Dip Tube 80 CTRKIT305 MONARCH 100 Dip Tube 100 2 CTRKIT307 All Drain 1 2 Not shown SMRKIT203 MONARCH 60 t...

Страница 28: ...ld Water Inlet Return to boiler Flow from boiler Drywell Drain Connection E F Fig 16 MONARCH Dimensions Top View Cold Water Inlet Hot Water Outlet Temperature and Pressure Relief Valve Connection 22 A...

Страница 29: ...NPT M 3 4 3 4 3 4 3 4 1 1 T P NPT F 3 4 3 4 3 4 3 4 3 4 3 4 Drain NPT F 1 2 1 2 1 2 1 2 1 2 1 2 Drywell 1 2 1 2 1 2 1 2 1 2 1 2 Dimensions Inches A 40 1 2 50 1 2 56 1 4 64 61 73 B 21 1 6 21 1 6 26 26...

Страница 30: ...ity MBH Peak Flow Gal 10 min 1st Hour Flow Gal Hour Continuous Flow Gal Hour Circulator Min GPM MONARCH 30 121 25 214 189 14 MONARCH 40 123 34 228 194 14 MONARCH 50 154 39 281 242 14 MONARCH 60 156 47...

Страница 31: ......

Страница 32: ...PP SST Outdoor Reset 95 AFUE High Efficiency Condensing Boiler Combi Power Range 80 110 155 175 250 299 399 MBH Turn Down Ratio up to 5 1 Natural Gas or Propane Outdoor Reset Brazed Plate Heat Exchan...