19
Installation and Servicing
SECTION 2 - INSTALLATION
INST
ALLA
TION
The wall mounting template is located on the internal protective
packaging. The template shows the position of the fixing and rear
flue centre holes for a standard installation
Care MUST be taken to ensure the correct holes are drilled.
1.
Tape template into the required position, ensuring its squareness
by hanging a plumbline as shown.
2.
If fitting a side flue, extend the flue centreline onto the side by
155mm
on a standard wall fix.
3.
Mark the following on to the wall:
a
The selected group of wall mounting screw holes.
b.
The centre position of the flue duct. Marking both the centre
and the circumference of the flue duct.
4.
Remove the template plate from the wall.
2.6 WALL MOUNTING TEMPLATE
2.7 PREPARING THE WALL
IMPORTANT.
Ensure that, during the cutting operation, masonry falling
outside of the building does not cause damage or personal
injury.
1.
Cut the flue hole (preferably with a 5” core boring tool),
ensuring that the hole is square to the wall.
Both wall faces immediately around the cut hole should be
flat.
2.
Drill 2 mounting holes (marked from template) with a 7.5mm
/ 8mm masonry drill and insert the plastic plugs, provided,
for the wall mounting plate.
3.
Locate 2 No.14 x 50mm screws in the wall mounting plate
(one at each side, in any of the 3 holes provided at each
side) and screw home. Ensure mounting bracket is level.
“A” - See Diagram in
Section 1.16
Extended centre line
155
3G9495
X
Section
through wall
Note.
Check all of the hole
positions before drilling.
Side flue only
5" diameter hole
Rear flue only
5" diameter hole
2.5 FRONT PANEL REMOVAL
1.
Loosen the 2 screws retaining the front panel.
2.
Pull the two clips downwards to disengage.
3.
Pull the front panel forward and upwards to remove.
1
2
Содержание LOGIC+ COMBI C35
Страница 2: ...2 Installation and Servicing ...