63
Installation and Servicing
SECTION 3 - SERVICING
SER
VICING
3.32 DHW FILTER AND FLOW REGULATOR CLEANING/REPLACEMENT
3.33 FLOW THERMISTOR REPLACEMENT
1. Refer to Sections 3.2 & 3.3.
2. Drain the DHW system. Refer to Section 3.24.
3. Turn the housing anti clockwise and pull forward to
remove the cartridge.
4. Using a pair of pliers, pull out the plastic filter/flow
regulator.
5. Clean or replace filter as necessary.
6. Reassemble in reverse order.
7. Refill the boiler. Refer to Section 2.15.
8. Check the operation of the boiler. Refer to Sections 2.25
to 2.27.
1. Refer to Sections 3.2 & 3.3.
2.
Unclip the flow thermistor.
3. Disconnect the electrical lead from the thermistor.
4. Reconnect the electrical lead to the new thermistor and
reassemble in reverse order, ensuring that the thermistor
is securely fitted to the pipe on the thermistor locator tabs
as shown.
5. Check the operation of the boiler. Refer to Sections 2.25
to 2.27.
2
3
3
4
Содержание VOGUE MAX COMBI 26
Страница 4: ...4 Installation and Servicing...
Страница 6: ...6 Installation and Servicing...
Страница 74: ......