Response 80 / 100 / 120
- Installation
GENERAL
OPERATION
With no call for CH the boiler fires only when DHW is drawn off.
When there is a call for CH, the heating system is supplied at the
selected temperature until DHW is drawn off. The full output of
the boiler is then directed by the automatic switching off of the
circulation pump to heat the inner coils and supply a maximum
draw-off of :
Response 80
9.6 l/min
(2.1 gpm)
at 35
0
rise
Response 100
12.0 l/min
(2.6 gpm)
at 35
0
rise
Response 120
14.4 l/min
(3.1 gpm)
at 35
0
rise.
The nominal DHW temperature is 60
o
C but water drawn off
when the boiler has been on for central heating may be hotter
than this, for a short period of time.
1