Response 80 / 100 / 120
- Installation
Maximum
Response 80
Response 100
Response 120
Burner pressure (hot)
mbar (in.w.g.)
13.2 (5.2)
10.2 (4.0)
13.2 (5.2)
Input based on nett CV
kW (Btu/h)
26.4 (90 000)
33 (112 500)
39.7 (135 100)
Input based on gross CV
kW (Btu/h)
29.3 (100 000)
36.7 (125 000)
44.0 (150 000)
Output
kW (Btu/h)
23.4 (80 000)
29.3 (100 000)
35.2 (120 000)
Gas consumption (Hot)
l/s (ft
3
/h)
0.757 (95)
0.95 (120)
1.14 (143)
Flow 35
o
C. temp. rise
l/m (gpm)
9.6 (2.1)
12.0 (2.6)
14.4 (3.2)
Domestic hot water specific rate
l/m (gpm)
11.2 (2.4)
14.6 (3.2)
17.1 (3.8)
Seasonal efficiency (SEDBUK) *
[79.4]%
[80.0]%
[80.0]%
PERFORMANCE DATA
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross or
34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different
calorific value:-
a. FOR L/S
- divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. FOR FT
3
/H
- divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
Gas supply type & connection
2H-G20-20mbar, 22mm copper
Inlet connection
Domestic Hot Water
15mm copper
Outlet connection
Domestic Hot Water
15mm copper
Flow & return connection
Central heating
22 mm - 28mm copper
Flue terminal diameter
mm (in.)
100 (4)
Max. working pressure (sealed systems) bar (lb/in
2
)
2.65 (38.5)
Electrical supply & loading
230 V ~ 50 Hz, 160W max
External fuse rating
3A
Internal fuse rating (BS 42 65)
PCB40 F1: 4ATASG
PCB40 F2: 2AF HRC
PCB41 F1: 2A HRC
Boiler size
Height mm (in.)
640 (25 3/16)
Width mm (in.)
436 (17 1/8)
Depth mm (in.)
278 (10 15/16)
Response 80
Response 100
Response 120
Average flue temp / mass flow rate
235
o
C / 11.8 g/s
235
o
C / 14.7 g/s
235
o
C / 14.7 g/s
Max. DHW water inlet pressure
bar (lb/in
2
)
10.0 (145.0)
10.0 (145.0)
10.0 (145.0)
Min. DHW water inlet pressure
bar (lb/in
2
)
1.0 (14)
1.2 (17)
1.2 (17)
Dry lift weight
kg (lb.)
50 (110)
51.2 (112)
51.2 (112)
Water content
Central heating litre (gal.)
1.7 (0.37)
1.7 (0.37)
1.7 (0.37)
Domestic hot water litre (gal.)
0.48 (0.11)
0.7 (0.15)
0.7 (0.15)
Table 1 - General Data
IMPORTANT.
This manual is applicable only to Response boilers with a data plate prefix of RF or above
Table 2 - Performance Data - CENTRAL HEATING
Max
Min
Max
Min
Max
Min
Burner pressure (hot)
mbar (in.w.g.)
7.2(3.1)
3.5 (1.5)
6.7 (2.6)
1.8 (0.7)
6.7 (2.6)
1.8 (0.7)
Input based on nett CV
kW (Btu/h)
19.8(67500) 12.6(43000)
26.4(90000)
13.2(45000)
26.4(90000)
13.2(45000)
Input based on gross CV
kW (Btu/h)
22(75000)
13.9(47500) 29.3(100000) 14.7(50000) 29.3(100000) 14.7(50000)
Output
kW (Btu/h)
17.6(60000) 11.7(40000)
23.4(80000)
11.7(40000)
23.4(80000)
11.7(40000)
Gas consumption (hot)
l/s (ft
3
/h)
0.568(72)
0.359(45)
0.757(95)
0.380(48)
0.757(95.4)
0.380(48)
Key to symbols
I E
= Ireland
GB
=United Kingdom (Countries of destination)
PMS
= Maximum operating pressure of water
C13,C33
=
A room sealed appliance designed for connection via ducts
to a horizontal or vertical terminal which admits fresh air to the
burner and discharges the products of combustion to the outside
through orifices which, in this case, are concentric. The fan is up
stream of the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
Table 3 - Performance Data - DOMESTIC HOT WATER
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by notified body.