17
Response 80 / 100 / 120
- Installation
15 CUTTING THE FLUE - Wall thicknesses up to 600mm (23
5/8
")
1. The flue cut length is
calculated as detailed in
Frame 10.
2. Measure from the groove and
mark the tube.
3. To ensure the tube is cut
square, mark the flue all the
way round using (e.g). a long
straight strip of paper with its
ends overlapped.
4. Cut to length, using the
cardboard support aid.
5. Remove the cardboard
support and any burrs.
For flue lengths greater than 600mm (23
5/8
") refer to Frames 30 to 32 -
Flue Extension Ducts
16
FITTING THE FLUE
IMPORTANT
To facilitate turret fixing or removal do NOT make good the wall.
1. Attach the clamping/sealing rings to the flue (this prevents the
assembly being pushed right through the hole and causing an
accident).
2. Pass the cut flue through the prepared hole, ensuring that the
groove is uppermost.
3. Pull the flue back to compress the rubber seal and fix in place
with the clamping/sealing rings.
REAR FLUE OUTLET
INSTALLATION