15
Response 80 / 100 / 120
- Installation
13
DRILLING THE WALL (Rear Flue)
IMPORTANT
. Ensure that, during the cutting operation,
masonry falling outside the building does not cause damage
or personal injury.
1. Cut the flue hole (preferably with a 5" core boring tool),
ensuring that the hole is square to the wall.
2. Measure and note the wall thickness 'W'.
3. Drill the 6 fixing holes with an 8mm (
5/16
") masonry drill.
Note.
If the terminal is to be sited within 25-40mm of a
corner or vertical pipe (refer to Table 5) then the hole MUST
be accurately cut and the rubber weather seal trimmed
around the groove provided.
(The terminal wall plate cannot be fitted close to a corner).
11
REAR FLUE ASSEMBLY - Exploded View
12
WALL MOUNTING TEMPLATE (Rear Flue)
IMPORTANT.
For direct mounting (wall mounting frame on wall)
choose one black dot in each group.
If using the stand-off channels choose one dotted circle
in each group. Care MUST be taken to ensure the
correct holes are drilled.
1. Tape the template into the selected position.
2. Ensure squareness by hanging a plumbline as
shown.
3. Mark onto the wall the following:
a.
The 6 wall mounting plate screw positions.
LEGEND
1. Terminal.
2. Weather seal.
3. Duct assembly.
4. Sealing ring.
5. Clamping ring.
6. No.8 x 8 self tapping screw.
7. Flue turret.
8. M5 x 10 pozi Hex screw.
9. Turret clamp.
INSTALLATION
REAR FLUE OUTLET
b.
The position of the flue duct.
Mark the centre of the hole as well as the circumference.
4. Remove the template from the wall.