Installation and Servicing
FLUE OUTLET
SECTION 2 - INSTALLATION
Note.
A flat or pitched roof flashing plate (not supplied) is required before proceeding
with the installation of this kit.
This kit is suitable for both flat and pitched
roof terminations, using a concentric flue to
run vertically from the top of the boiler and
terminating above roof level.
Connection to the top of the boiler is made
using a separately supplied vertical connector.
WEATHER PROOFING
Where the flue passes through the roof line an
adequate seal must be made. This is achieved
by using either:
- Flat roof weather collar
or
- Universal weather collar.
ACCESSORIES
Flue Duct Extension Kits are available for
flue lengths extending beyond 1m. These
packs contain 500mm, 1000mm and 2000mm
extension ducts and may be cut to the desired
length.
If the offset vertical option is used an elbow Kit
is required.
For a full accessories list refer to www.
idealboilers.com.
2.16 FITTING THE OPTIONAL ROOF FLUE KIT (Flat or Pitched)