19
INSTALLATION
Classic
Slimline FF
-
Installation & Servicing
SIDE FLUE OUTLET
1. The boiler is supplied for rear
outlet installation. Remove the
blanking plate from the
direction required and use this
to blank off the rear outlet.
2. Lift the boiler onto the wall
mounting plate, as shown.
Do not use the burner/
controls for lifting.
3. Fit the No. 14 x 50mm wood
screw, washer and rectangular
plate to retain the boiler.
Note.
Before fully tightening the
retaining screw check the boiler
alignment, using a spirit level, and
adjust as necessary with the
jacking screw.
1. Fix the mounting plate to the wall with the No.14 x 50mm
wood screws.
2. Check with a spirit level that the plate is horizontal.
3. Cupboard Supports
In some applications existing wooden supports may
hinder the removal of the casing. 2 cupboard supports
are provided for the top and bottom of the opening.
These should be positioned to allow the casing to be
removed in servicing.
28 FITTING THE SIDE OUTLET PLATES
30 MOUNTING THE BOILER
Note.
If the boiler is fitted closer than 25mm to the side wall
the side outlet plate must be fitted now.
1. Split the side outlet plate into 2 down the split line.
2. Fit the 2 halves of the side outlet plate to the wall,
ensuring they are behind the boiler sealing ring.
Jacking
screw
Clas
1750-2
29 WALL MOUNTING PLATE
SIDE FLUE OUTLET