80
Installation and Maintenance
Service Manual
a
b
Procedure
Steps
7. Remove electric box assy
6. Remove vertical louver
Loosen the connection clasps between shield
cover of electric box sub-assy and electric box,
and then remove the shield cover of electric
box sub-assy.
Cut off the tieline which binding the temperature
sensor and grounding wire on the evaporator,
and then pull out the indoor tube temperature
sensor from the evaporator.
Remove the screws at the connection place
between grounding wire and evaporator.
Pull out the wiring terminal of motor and wiring
terminal of step motor from the mainboard.
Note:
1.Location of tube temperature sensor and
tieline on the evaporator is different for different
models.
2.When pulling out the wiring terminal, pay
attention to loose the clasp and don’t pull it so
hard.
Loosen the connection clasps between vertical
louver and bottom case to remove vertical
louver.
vertical louver
bottom
case
clasps
clasps
shield cover of electric box sub-assy
electric box
temperature sensor
grounding wire
evaporator
Location of
grounding
wire screw
wiring
terminal
of motor
wiring terminal
of step motor